前往化源商城

2,4-二硝基苯乙酸

2,4-二硝基苯乙酸结构式
2,4-二硝基苯乙酸结构式
品牌特惠专场
常用名 2,4-二硝基苯乙酸 英文名 (2,4-Dinitrophenyl)acetic acid
CAS号 643-43-6 分子量 226.143
密度 1.6±0.1 g/cm3 沸点 430.2±30.0 °C at 760 mmHg
分子式 C8H6N2O6 熔点 169-175 °C(lit.)
MSDS 中文版 美版 闪点 191.8±13.0 °C
符号 GHS07
GHS07
信号词 Warning

A reinvestigation of the pre-steady-state ATPase activity of the nitrogenase from Azotobacter vinelandii.

Eur. J. Biochem. 208(2) , 289-94, (1992)

The pre-steady-state ATPase activity of nitrogenase has been reinvestigated. The exceptionally high burst in the hydrolysis of MgATP by the nitrogenase from Azotobacter vinelandii communicated by Cordewener et al. (1987) [Cordewener J., ten Asbroek A., Wassin...

Synthesis of a parabactin photoaffinity label. Bergeron RJ, et al.

J. Org. Chem. 52(1) , 144-49, (1987)

The coupling of diazonium salts with aliphatic carbon atoms. Parmerter SM.

Org. React. , (1959)

A self-assembled nanofiber catalyst for ester hydrolysis.

J. Am. Chem. Soc. 129(40) , 12082-3, (2007)

A simple rapid mixing device.

Anal. Biochem. 106(1) , 73-7, (1980)

Kinetic evidence for a substrate-induced fit in phosphonoacetaldehyde hydrolase catalysis.

Biochemistry 41(45) , 13370-7, (2002)

Phosphonoacetaldehyde hydrolase (phosphonatase) from Bacillus cereus catalyzes hydrolytic P-C bond cleavage of phosphonoacetaldehyde (Pald) via a Schiff base intermediate formed with Lys53. A single turnover requires binding of Pald to the active site of the ...

A quenched-flow technique for the measurement of glucose influx into human red blood cells.

Anal. Biochem. 144(2) , 385-9, (1985)

A quenched-flow apparatus is described and applied to measurements of the hydrolysis of 2,4-dinitrophenyl acetate by sodium hydroxide and the entry of D-[U-14C]glucose into human red blood cells at 37 degrees C. Glucose influx into red cells was a saturable p...

Construction of a microprocessor-controlled pulsed quench-flow apparatus for the study of fast chemical and biochemical reactions.

Anal. Biochem. 142(1) , 91-7, (1984)

The construction and operation of a microprocessor-controlled quenched-flow machine are described. Two sets of syringes are moved by high-torque stepping motors to achieve any desired mixing scheme. The dead time of the instrument is pulsed quench-flow operat...

An apparatus for sequentially combining microvolumes of reagents by infrasonic mixing.

Anal. Biochem. 138(2) , 329-34, (1984)

A method employing high-speed infrasonic mixing for obtaining timed samples for following the progress of a moderately rapid chemical reaction is described. Drops of 10 to 50 microliter each of two reagents are mixed to initiate the reaction, followed, after ...