Acetophenone

Acetophenone Structure
Acetophenone structure
Common Name Acetophenone
CAS Number 98-86-2 Molecular Weight 120.148
Density 1.0±0.1 g/cm3 Boiling Point 202.0±0.0 °C at 760 mmHg
Molecular Formula C8H8O Melting Point 19.6ºC
MSDS Chinese USA Flash Point 82.2±0.0 °C
Symbol GHS07
GHS07
Signal Word Warning

Convenient QSAR model for predicting the complexation of structurally diverse compounds with β-cyclodextrins

Bioorg. Med. Chem. 17 , 896-904, (2009)

This paper reports a QSAR study for predicting the complexation of a large and heterogeneous variety of substances (233 organic compounds) with beta-cyclodextrins (beta-CDs). Several different theoretical molecular descriptors, calculated solely from the mole...

Calculating virtual log P in the alkane/water system (log P(N)(alk)) and its derived parameters deltalog P(N)(oct-alk) and log D(pH)(alk).

J. Med. Chem. 48 , 3269-79, (2005)

Growing interest in the use of both the logarithm of the partition coefficient of the neutral species in the alkane/water system (log P(N)(alk)) and the difference between log P(N)(oct) (the logarithm of the partition coefficient of the neutral species in the...

One-pot synthesis of 2-phenylimidazo[1,2-α]pyridines from acetophenone, [Bmim]Br(3) and 2-aminopyridine under solvent-free conditions.

Molecules 17(11) , 13368-75, (2012)

One-pot synthesis of 2-phenylimidazo[1,2-α]pyridines from acetophenone, [Bmim]Br(3) and 2-aminopyridine under solvent-free conditions in the presence of Na(2)CO(3), gave the corresponding 2-phenylimidazo[1,2-α]pyridines in excellent yields ranging from 72% to...

Repetitive injection method: a tool for investigation of injection zone formation and its compression in microfluidic liquid chromatography.

J. Chromatogr. A. 1381 , 110-7, (2015)

Sample introduction in microfluidic liquid chromatography often generates wide zones rather than peaks, especially when a large sample volume (relative to column volume) is injected. Formation of wide injection zones can be further amplified when the sample i...

Wide injection zone compression in gradient reversed-phase liquid chromatography.

J. Chromatogr. A. 1390 , 86-94, (2015)

Chromatographic zone broadening is a common issue in microfluidic chromatography, where the sample volume introduced on column often exceeds the column void volume. To better understand the propagation of wide chromatographic zones on a separation device, a s...

Development and application of a non-targeted extraction method for the analysis of migrating compounds from plastic baby bottles by GC-MS.

Food Addit. Contam. Part A. Chem. Anal. Control. Expo. Risk Assess. 31(12) , 2090-102, (2014)

In 2011, the European Union prohibited the production of polycarbonate (PC) baby bottles due to the toxic effects of the PC monomer bisphenol-A. Therefore, baby bottles made of alternative materials, e.g. polypropylene (PP) or polyethersulphone (PES), are cur...

Mosquito odorant receptor for DEET and methyl jasmonate.

Proc. Natl. Acad. Sci. U. S. A. 111(46) , 16592-7, (2014)

Insect repellents are important prophylactic tools for travelers and populations living in endemic areas of malaria, dengue, encephalitis, and other vector-borne diseases. DEET (N,N-diethyl-3-methylbenzamide) is a 6-decade-old synthetic repellent, which is st...

Toward prediction of alkane/water partition coefficients.

J. Med. Chem. 51 , 3720-30, (2008)

Partition coefficients were measured for 47 compounds in the hexadecane/water ( P hxd) and 1-octanol/water ( P oct) systems. Some types of hydrogen bond acceptor presented by these compounds to the partitioning systems are not well represented in the literatu...

A chemical screening approach reveals that indole fluorescence is quenched by pre-fibrillar but not fibrillar amyloid-beta.

Bioorg. Med. Chem. Lett. 19 , 4952-7, (2009)

Aggregated amyloid-beta (Abeta) peptide is implicated in the pathology of Alzheimer's disease. In vitro and in vivo, these aggregates are found in a variety of morphologies, including globular oligomers and linear fibrils, which possess distinct biological ac...

Efficiency of short, small-diameter columns for reversed-phase liquid chromatography under practical operating conditions.

J. Chromatogr. A. 1383 , 47-57, (2015)

Prototype small-size (1.0mm I.D., 5cm long) columns for reversed-phase HPLC were evaluated in relation to instrument requirements. The performance of three types of columns, monolithic silica and particulate silica (2μm, totally porous and 2.6μm, core-shell p...