前往化源商城

钙离子载体II

钙离子载体II结构式
钙离子载体II结构式
品牌特惠专场
常用名 钙离子载体II 英文名 N,N,N′,N′-Tetracyclohexyl-3-oxapentanediamide
CAS号 74267-27-9 分子量 460.69
密度 1.07g/cm3 沸点 613.7ºC at 760 mmHg
分子式 C28H48N2O3 熔点 N/A
MSDS 美版 闪点 325ºC

Indo-1 binding to protein in permeabilized ventricular myocytes alters its spectral and Ca binding properties.

Biophys. J. 63(1) , 89-97, (1992)

We have examined the binding of the fluorescent Ca indicator indo-1 to cellular protein in permeabilized ventricular myocytes and also to soluble and particulate myocyte protein. Using either a filtration technique or equilibrium dialysis, and conditions simi...

Ion-selective electrode for measuring low Ca2+ concentrations in the presence of high K+, Na+ and Mg2+ background.

Anal. Chem. 69 , 1061-1069, (1997)

In this work, ion-selective electrodes for calcium ion were investigated. Two ionophores were used in the membranes: ETH 1001 and ETH 129. An internal filling solution buffered for primary ion was used that allowed the lower detection limit to be decreased do...

Induction of a non-specific permeability transition in mitochondria from Yarrowia lipolytica and Dipodascus (Endomyces) magnusii yeasts.

J. Bioenerg. Biomembr. 41(3) , 239-49, (2009)

In this study we used tightly-coupled mitochondria from Yarrowia lipolytica and Dipodascus (Endomyces) magnusii yeasts, possessing a respiratory chain with the usual three points of energy conservation. High-amplitude swelling and collapse of the membrane pot...

Release of Ca2+ and Mg2+ from yeast mitochondria is stimulated by increased ionic strength.

BMC Biochem. 7 , 4, (2006)

Divalent cations are required for many essential functions of mitochondrial metabolism. Yet the transporters that mediate the flux of these molecules into and out of the mitochondrion remain largely unknown. Previous studies in yeast have led to the molecular...

A study of calcium ion-selective PVC membrane electrode based on neutral carrier N,n,n',n'-tetracyclo-3-oxapentanediamide (correction of oxapetanediamide).

J. Tongji Med. Univ. 12(2) , 98-102, (1992)

A calcium ion-selective PVC membrane electrode based on neutral carrier n,n,n',n'-tetracyclohexyl-3-oxapetanediamide, using di-(2-ethylhexyl)phthalate as the plasticizer and potassium tetrakis (4-chlorophenyl) borate as the additive is reported in this paper....

The ionophore ETH 129 as Ca2+ translocator in artificial and natural membranes.

Anal. Biochem. 210(1) , 119-22, (1993)

We have investigated the ability of the neutral ionophore ETH 129 to translocate Ca2+ across artificial and biological membranes. ETH 129 induces Ca2+ transport across planar lipid bilayer. The zero-current membrane potential in a gradient of Ca2+ concentrati...

Chronoamperometry at micropipet electrodes for determination of diffusion coefficients and transferred charges at liquid/liquid interfaces.

Anal. Chem. 76(18) , 5570-8, (2004)

Chronoamperometry was carried out at liquid/liquid interfaces supported at the tip of micropipet electrodes for direct determination of the diffusion coefficient of a species in the outer solution. The diffusion coefficient was used for subsequent determinati...

New flow-through analytical system based on ion-selective field effect transistors with optimised calcium selective photocurable membrane for bovine serum analysis

Talanta 113 , 31-5, (2013)

An analytical system based on ion-selective field effect transistors (ISFETs) with Ca2+ ion selective photocurable membranes is developed to offer a semiautomatic analysis of serum calcium concentration of ruminants. Optimisation of ion-sensitive membrane com...

The endogenous CXXC motif governs the cadmium sensitivity of the renal Na+/glucose co-transporter.

J. Am. Soc. Nephrol. 16(5) , 1257-65, (2005)

Cadmium (Cd2+) poisoning causes severe renal disorders manifested by defects in reabsorptive transport of various compounds. It is reported here that the renal brush-border membrane Na+/glucose co-transporter-1 (SGLT1) is a molecular target for Cd2+ toxicity....