N,N,N′,N′-Tetracyclohexyl-3-oxapentanediamide structure
|
Common Name | N,N,N′,N′-Tetracyclohexyl-3-oxapentanediamide | ||
|---|---|---|---|---|
| CAS Number | 74267-27-9 | Molecular Weight | 460.69 | |
| Density | 1.07g/cm3 | Boiling Point | 613.7ºC at 760 mmHg | |
| Molecular Formula | C28H48N2O3 | Melting Point | N/A | |
| MSDS | USA | Flash Point | 325ºC | |
Use of N,N,N′,N′-Tetracyclohexyl-3-oxapentanediamideN,N,N′,N′-Tetracyclohexyl-3-oxapentanediamide (Calcium ionophore II) is a lipophilic ionophore that can be used in preparing calcium ion-selective electrode[1]. |
| Name | calcium ionophore ii |
|---|---|
| Synonym | More Synonyms |
| Description | N,N,N′,N′-Tetracyclohexyl-3-oxapentanediamide (Calcium ionophore II) is a lipophilic ionophore that can be used in preparing calcium ion-selective electrode[1]. |
|---|---|
| Related Catalog | |
| In Vitro | Calcium ion-selective electrode can be used to measure the intracellular free calcium[1]. |
| References |
| Density | 1.07g/cm3 |
|---|---|
| Boiling Point | 613.7ºC at 760 mmHg |
| Molecular Formula | C28H48N2O3 |
| Molecular Weight | 460.69 |
| Flash Point | 325ºC |
| Exact Mass | 460.36600 |
| PSA | 49.85000 |
| LogP | 5.99100 |
| Index of Refraction | 1.536 |
| Personal Protective Equipment | dust mask type N95 (US);Eyeshields;Gloves |
|---|---|
| Hazard Codes | Xi: Irritant; |
| Risk Phrases | 37 |
| Safety Phrases | 22-24/25 |
| RIDADR | NONH for all modes of transport |
| WGK Germany | 3 |
|
~11%
N,N,N′,N′-Tetra... CAS#:74267-27-9 |
| Literature: Pretsch, Erno; Ammann, Daniel; Osswald, Hans F.; Guggi, Marc; Simon, Wilhelm Helvetica Chimica Acta, 1980 , vol. 63, # 1 p. 191 - 196 |
| Precursor 2 | |
|---|---|
| DownStream 0 | |
|
Indo-1 binding to protein in permeabilized ventricular myocytes alters its spectral and Ca binding properties.
Biophys. J. 63(1) , 89-97, (1992) We have examined the binding of the fluorescent Ca indicator indo-1 to cellular protein in permeabilized ventricular myocytes and also to soluble and particulate myocyte protein. Using either a filtra... |
|
|
Ion-selective electrode for measuring low Ca2+ concentrations in the presence of high K+, Na+ and Mg2+ background.
Anal. Chem. 69 , 1061-1069, (1997) In this work, ion-selective electrodes for calcium ion were investigated. Two ionophores were used in the membranes: ETH 1001 and ETH 129. An internal filling solution buffered for primary ion was use... |
|
|
Induction of a non-specific permeability transition in mitochondria from Yarrowia lipolytica and Dipodascus (Endomyces) magnusii yeasts.
J. Bioenerg. Biomembr. 41(3) , 239-49, (2009) In this study we used tightly-coupled mitochondria from Yarrowia lipolytica and Dipodascus (Endomyces) magnusii yeasts, possessing a respiratory chain with the usual three points of energy conservatio... |
| N,N,N',N',-Tetracyclohexyl-3-oxapentandiamin |
| N,N,N',N'-TETRACYCLOHEXYL-3-OXAPENTANEDIAMIDE |
| ETH 129 |