![]() ROX-SE structure
|
Common Name | ROX-SE | ||
---|---|---|---|---|
CAS Number | 209734-74-7 | Molecular Weight | 631.67400 | |
Density | N/A | Boiling Point | N/A | |
Molecular Formula | C37H33N3O7 | Melting Point | N/A | |
MSDS | Chinese USA | Flash Point | N/A | |
Symbol |
![]() GHS07 |
Signal Word | Warning |
High-resolution liquid chromatography of fluorescent dye-labeled nucleic acids.
Anal. Biochem. 223 , 39, (1994) Using 100 mM of triethylammonium acetate as ion-pairing reagent, phosphodiester oligonucleotides labeled fluorescently at their 5' terminus could be separated successfully on alkylated nonporous 2.3-microns poly(styrene-divinylbenzene) particles by means of h... |
|
DNA sequencing with dye-labeled terminators and T7 DNA polymerase: effect of dyes and dNTPs on incorporation of dye-terminators and probability analysis of termination fragments.
Nucleic Acids Res. 20 , 2471, (1992) The incorporation of fluorescently labeled dideoxynucleotides by T7 DNA polymerase is optimized by the use of Mn2+, fluorescein analogs and four 2'-deoxyribonucleoside 5'-O-(1-thiotriphosphates) (dNTP alpha S's). The one-tube extension protocol was tested on ... |
|
Synthesis and application of charge-modified dye-labeled dideoxynucleoside-5'-triphosphates to 'direct-load' DNA sequencing.
Nucleic Acids Res. 30 , 2877, (2002) A novel series of charge-modified, dye-labeled 2',3'-dideoxynucleoside-triphosphate terminators were synthesized and evaluated as reagents for DNA sequencing. These terminators possess an advantage over existing reagents in that no purification is required to... |
|
Porphyrin FRET acceptors for apoptosis induction and monitoring.
J. Am. Chem. Soc. 133 , 18580-18582, (2011) Photodynamic therapy (PDT) stands to benefit from improved approaches to real-time treatment monitoring. One method is to use activatable photosensitizers that can both induce cell death (via singlet oxygen) and monitor it (via caspase detection). Here, we re... |
|
Dual color fluorescence quantitative detection of specific single-stranded DNA with molecular beacons and nucleic acid dye SYBR Green I.
Analyst 137 , 3787-3793, (2012) We have developed a dual color fluorescence quantitative detection method for specific single-stranded DNA with molecular beacons (MBs) and nucleic acid dye SYBR Green I by synchronous scanning fluorescence spectrometry. It is demonstrated by a reverse-transc... |
|
A positively charged QDs-based FRET probe for micrococcal nuclease detection.
Analyst 135 , 2394-2399, (2010) A new strategy for quantitatively detecting micrococcal nuclease (MNase) is proposed using electrostatic interaction-based fluorescence resonance energy transfer (FRET) between positively charged QDs and negatively charged dye-labeled single-stranded DNA (dye... |
|
Multiplex detection of endonucleases by using a multicolor gold nanobeacon.
Chemistry 17 , 7313-7319, (2011) A highly sensitive and selective assay based on a novel enzyme-responsive multicolor gold nanobeacon has been developed for the multiplex detection of endonucleases, a group of very important nucleases. The nanobeacon takes advantage of the high specificity o... |
|
Droplet-based microscale colorimetric biosensor for multiplexed DNA analysis via a graphene nanoprobe.
Anal. Chim. Acta 751 , 155-160, (2012) The development of simple and inexpensive DNA detection strategy is very significant for droplet-based microfluidic system. Here, a droplet-based biosensor for multiplexed DNA analysis is developed with a common imaging device by using fluorescence-based colo... |
|
Aptasensor based on triplex switch for SERS detection of cytochrome c.
Analyst 137 , 5705-5709, (2012) We report a sensitive approach for SERS detection of cytochrome c using target binding-induced conformational changes of signal transduction probe (STP). STP labeled with a SERS-active molecule, carboxy-X-rhodamine (ROX), is immobilized on the substrate where... |