前往化源商城

Analytica Chimica Acta 2014-06-27

Sensitive and selective cocaine electrochemical detection using disposable sensors.

Laura Asturias-Arribas, M Asunción Alonso-Lomillo, Olga Domínguez-Renedo, M Julia Arcos-Martínez

文献索引:Anal. Chim. Acta 834 , 30-6, (2014)

全文:HTML全文

摘要

This paper describes the voltammetric determination of cocaine in presence of three different interferences that could be found in street samples using disposable sensors. The electrochemical analysis of this alkaloid can be affected by the presence of codeine, paracetamol or caffeine, whose oxidation peaks may overlap and lead to false positives. This work describes two different solutions to this problem. On one hand, the modification of disposable carbon sensors with carbon nanotubes allows the voltammetric quantification of cocaine by using ordinary least squares regressions in the concentration range from 10 to 155 μmol L(-1), with a reproducibility of 5.6% (RSD, n = 7. On the other hand, partial least squares regressions are used for the resolution of the overlapped voltammetric signals when using screen-printed carbon electrodes without any modification. Both procedures have been successfully applied to the evaluation of the purity of cocaine street samples.Copyright © 2014 Elsevier B.V. All rights reserved.

相关化合物

结构式 名称/CAS号 全部文献
丙酮 结构式 丙酮
CAS:67-64-1
氯仿 结构式 氯仿
CAS:67-66-3
氢氧化钠 结构式 氢氧化钠
CAS:1310-73-2
对乙酰氨基苯酚 结构式 对乙酰氨基苯酚
CAS:103-90-2
硝酸钾 结构式 硝酸钾
CAS:7757-79-1
咖啡因 结构式 咖啡因
CAS:58-08-2
3-乙基-2,4-戊烷二酮 结构式 3-乙基-2,4-戊烷二酮
CAS:1540-34-7
potassium,dioxido(oxo)azanium 结构式 potassium,dioxido(oxo)azanium
CAS:1173018-94-4
盐酸古柯碱 结构式 盐酸古柯碱
CAS:53-21-4