2-(5-bromo-2-pyridylazo)-5-diethylaminophenol

2-(5-bromo-2-pyridylazo)-5-diethylaminophenol Structure
2-(5-bromo-2-pyridylazo)-5-diethylaminophenol structure
Common Name 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol
CAS Number 14337-53-2 Molecular Weight 349.226
Density 1.4±0.1 g/cm3 Boiling Point 511.1±50.0 °C at 760 mmHg
Molecular Formula C15H17BrN4O Melting Point 155-160 °C
MSDS Chinese USA Flash Point 262.9±30.1 °C

Determination of Lead in Water Samples Using a New Vortex-Assisted, Surfactant-Enhanced Emulsification Liquid-Liquid Microextraction Combined with Graphite Furnace Atomic Absorption Spectrometry.

Arch. Environ. Contam. Toxicol. 70 , 607-14, (2016)

A low toxic solvent-based vortex-assisted surfactant-enhanced emulsification liquid-liquid microextraction (LT-VSLLME) combined with graphite furnace atomic absorption spectrometry was developed for the extraction and determination of lead (Pb) in water sampl...

Development of an extractive spectrophotometric method for estimation of uranium in ore leach solutions using 2-ethylhexyl phosphonic acid-mono-2-ethylhexyl ester (PC88A) and tri-n-octyl phosphine oxide (TOPO) mixture as extractant and 2-(5-bromo-2-pyridylozo)-5-diethyl aminophenol (Br-PADAP) as chromophore.

Spectrochim. Acta. A. Mol. Biomol. Spectrosc. 91 , 222-7, (2012)

An extractive spectrophotometric analytical method has been developed for the determination of uranium in ore leach solution. This technique is based on the selective extraction of uranium from multielement system using a synergistic mixture of 2-ethylhexyl p...

Flame atomic absorption spectrometric determination of trace amounts of manganese in alloys and biological samples after preconcentration with the ion pair of 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol and ammonium tetraphenylborate on microcrystalline naphthalene or by column method.

Anal. Sci. 17(8) , 969-73, (2001)

Manganese is quantitatively retained on 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP)-ammonium tetraphenylborate with microcrystalline naphthalene or by a column method in the pH range 7.5-10.5 from large volumes of aqueous solutions of various s...

Modulation by Zn2+ of GABA responses in bipolar cells of the mouse retina.

Vis. Neurosci. 17(2) , 273-81, (2000)

The localization of endogenous Zn2+ in the mouse retina was examined histochemically and the inhibitory action of Zn2+ on GABA-induced responses was studied in bipolar cells isolated from the mouse retina. Accumulation of endogenous Zn2+ was detected in photo...

Chelates of cobalt(III) and iron(II) with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol as test probes for the characterization of chromatographic effects on a reversed-phase liquid chromatography stationary phase.

J. Chromatogr. A. 1099(1-2) , 111-20, (2005)

The chromatographic effects on a reversed-phase liquid chromatography (RPLC) phase were established with the use of chelates system: cobalt(III) and iron(II) with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol as the test probes. Both chelates have the same oc...

Simple regression model using an optode for the simultaneous determination of zinc and cadmium mixtures in aqueous samples.

Anal. Sci. 17(1) , 181-6, (2001)

An optical-fiber chemical sensor (optode) is described for the simultaneous determination of Zn2+ and Cd2+ mixtures using 2-(5-bromo-2-pyridylazo)-5-(diethylamino)phenol immobilized onto XAD-4 (Br-PADAP/XAD-4). A simultaneous analysis was achieved by using a ...

Highly sensitive chelating agents for histochemical staining of rare earth metals.

Histochem. Cell Biol. 112(2) , 179-82, (1999)

In tissues, bromopyridylazo-diethylaminophenol has been found to be capable of staining very small amounts of rare earth metals, particularly praseodymium, terbium, dysprosium, holmium, ytterbium, and lutetium. Differentiation of a target metal from interferi...

Optical test strip for trace Hg(II) based on doped sol-gel film.

Spectrochim. Acta. A. Mol. Biomol. Spectrosc. 72(1) , 32-5, (2009)

Optical test strip based on the use of Br-PADAP as a sensitive reagent immobilised into sol-gel thin film for detection of Hg(II) in aqueous solution had been thoroughly carried out. It has a square-sensing zone (1.0 cm x 1.0 cm) containing the sensitive reag...

Flame atomic absorption spectrometric determination of trace amounts of nickel after extraction and preconcentration onto natural modified analcime zeolite loaded with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol.

J. AOAC Int. 88(3) , 842-6, (2005)

Nickel is a moderately toxic element compared with other transition metals. However, inhalation of nickel and its compounds leads to serious problems, including cancer of the respiratory system and a skin disorder, nickel-eczema. Thus, attention has focused o...

Determination of trace amounts of cobalt(II) by flow injection-solid phase spectrometry (FI-SPS) with 5-Br-PADAB.

Anal. Sci. 22(1) , 177-81, (2006)

Flow injection-solid phase spectrometry (FI-SPS) has been applied to the determination of cobalt(II) in water samples. The complex formed between cobalt and 5-Br-PADAB was on-line protonated and concentrated on an AG 50W-X2 cation-exchanger in a flow-through ...