Polythene

Polythene Structure
Polythene structure
Common Name Polythene
CAS Number 9002-88-4 Molecular Weight N/A
Density 0.95 Boiling Point 48-110 °C(Press: 9 Torr)
Molecular Formula (C2H4)n Melting Point 92 °C
MSDS Chinese USA Flash Point 270 °C

Long-term hip simulator testing of the artificial hip joint bearing surface grafted with biocompatible phospholipid polymer.

J. Orthop. Res. 32(3) , 369-76, (2014)

To prevent periprosthetic osteolysis and subsequent aseptic loosening of artificial hip joints, we recently developed a novel acetabular highly cross-linked polyethylene (CLPE) liner with graft polymerization of 2-methacryloyloxyethyl phosphorylcholine (MPC) ...

Ultrasound assisted dialysis of semi-permeable membrane devices for the simultaneous analysis of a wide number of persistent organic pollutants.

Talanta 114 , 32-7, (2013)

A new procedure based on ultrasound assisted dialysis (UAD) for the simultaneous and quantitative extraction of a wide number of persistent organic pollutants (POPs) such as polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs) or some oth...

Hybrid composite membranes based on polyethylene separator and Al2O3 nanoparticles for lithium-ion batteries.

J. Nanosci. Nanotechnol. 13(5) , 3705-10, (2013)

A hybrid composite membrane is prepared by coating nano-sized Al2O3 powder (13 and 50 nm) and poly(vinylidene fluoride-co-hexafluoropropene) (P(VdF-co-HFP)) binder on both sides of polyethylene separator. The composite membrane shows better thermal stability ...

Polyethylene wear and osteolysis after cementless total hip arthroplasty with alumina-on-highly cross-linked polyethylene bearings in patients younger than thirty years of age.

J. Bone Joint Surg. Am. 95(12) , 1088-93, (2013)

We asked whether cementless total hip arthroplasties that made use of alumina-on-highly cross-linked polyethylene bearings would improve hip score and functional activity and reduce the prevalence of polyethylene wear, osteolysis, and aseptic loosening.Consec...

Application of nano-TiO2/LDPE composite film on photocatalytic oxidation degradation of dichloromethane.

J. Environ Biol. 33(5) , 955-9, (2012)

This study focused on the photocatalytic destruction of dichloromethane (DCM) in indoor air using the nano-TiO2/LDPE composite film as an economical photocatalyst. The nano-TiO2 was dispersed in a polyethylene matrix to form composite film. The photocatalytic...

Behavioral pattern of physicochemical constituents of the postharvest mango (Mangifera indica L.) influenced by storage stimuli.

Pak. J. Biol. Sci. 16(24) , 1985-90, (2013)

An investigation was carried at the laboratory of the Department of Biochemistry and Molecular Biology, University of Rajshahi, Bangladesh during the period from May, 2010 to September, 2011 to study the behavioral pattern of some physicochemical constituents...

Stability of calcium folinate (Teva) in concentrate after re-use and in dilute infusions in 0.9% NaCl in polyethylene bags.

Acta Pol. Pharm. 70(2) , 301-7, (2013)

The study concerned the stability of calcium folinate in concentrate in glass vials and diluted in polyethylene (PE) bags stored at 15-25 degrees C and 2-8 degrees C for up to 34 days. Original vials of calcium folinate injection (10 mg/mL, Teva) were stored ...

Development of the first certified reference materials for several brominated flame retardants in polymers.

Anal. Chem. 81 , 3792-3800, (2009)

The first reference materials certified for several polybrominated flame retardants in polymers were developed. Commercially available polyethylene and polypropylene were fortified with technical mixtures of Pentabrominated diphenylether (Penta-BDE), Octa-BDE...

Electrospray ionization on porous spraying tips for direct sample analysis by mass spectrometry: enhanced detection sensitivity and selectivity using hydrophobic/hydrophilic materials as spraying tips.

Rapid Commun. Mass Spectrom. 27(6) , 713-21, (2013)

Despite various porous materials having been widely adopted as spraying tips for direct sample analysis using electrospray ionization mass spectrometry (ESI-MS), the effect of surface property and porosity of spraying tip materials on their analytical perform...

Effects of extractives on some properties of bagasse/high density polypropylene composite.

Carbohydr. Polym. 94(1) , 416-9, (2013)

In this study, the effects of two variable parameters, namely the extractives and filler loading level, on the physical properties of composites were examined. Composites based on high density polyethylene (HDPE), bagasse flour (BF) as filler were made by inj...