前往化源商城

Talanta 2015-08-15

Application of surfactant-templated ordered mesoporous material as sorbent in micro-solid phase extraction followed by liquid chromatography-triple quadrupole mass spectrometry for determination of perfluorinated carboxylic acids in aqueous media.

Maryam Lashgari, Chanbasha Basheer, Hian Kee Lee

文献索引:Talanta 141 , 200-6, (2015)

全文:HTML全文

摘要

In the present study, micro-solid phase extraction (µ-SPE) followed by liquid chromatography-triple tandem mass spectrometery (LC-MS/MS) was developed for the determination of perfluorocarboxylic acids (PFCAs) at trace levels in water samples. The µ-SPE device comprised of a porous polypropylene membrane bag containing 5mg sorbent. The membrane bag acted as a clean-up filter and prevented matrix compounds from interfering with the extraction process. Analysis was carried out by LC-MS/MS in negative electrospray ionization mode. MS/MS parameters were optimized for multiple reaction monitoring. Calcined and non-calcined MCM-41, as silica-ordered mesoporous materials, were used as sorbents in µ-SPE for the extraction of five PFCAs-perfluoropentanoic acid (PFPA), perfluoroheptanoic acid (PFHpA), perfluorooctanoic acid (PFOA), perfluorononanoic acid (PFNA), and perfluorodecanoic acid (PFDA)-from aqueous media. The performances of these two sorbents were compared with other sorbents such as octadecylsilane (C18) modified silica, HayeSep-A, HayeSep-B, and Porapak-R. It was found that non-calcined MCM-41 showed better extraction performance for the analytes considered. Parameters influencing extraction efficiency, such as desorption time, extraction time, desorption solvent, and salt concentration, were investigated. The effect of the matrix on MS signals (suppression or enhancement) was also evaluated. Only minor effects on ionization efficiencies were observed. The developed method proved to be convenient and offered good sensitivity and reproducibility. The limits of detection ranged from 0.02 to 0.08ng L(-1), with a relative standard deviations between 1.9 and 10.5. It was successfully applied to the extraction of PFCAs in river and rain water samples. As expected from the ubiquitous nature of PFCAs, contamination at low levels was detected for some analytes in the samples (with the highest concentration recorded for PFOA). Satisfactory relative recoveries ranging between 64% and 127% at spiking levels of 10ng L(-1) of each analyte were obtained.Copyright © 2015 Elsevier B.V. All rights reserved.

相关化合物

结构式 名称/CAS号 全部文献
丙酮 结构式 丙酮
CAS:67-64-1
正己烷 结构式 正己烷
CAS:110-54-3
乙酸铵 结构式 乙酸铵
CAS:631-61-8
乙腈 结构式 乙腈
CAS:75-05-8
甲醇 结构式 甲醇
CAS:67-56-1
二氯甲烷 结构式 二氯甲烷
CAS:75-09-2
二乙烯苯 结构式 二乙烯苯
CAS:1321-74-0
十六烷基三甲基溴化铵 结构式 十六烷基三甲基溴化铵
CAS:57-09-0
全氟辛酸 结构式 全氟辛酸
CAS:335-67-1
N-乙烯基吡咯烷酮 结构式 N-乙烯基吡咯烷酮
CAS:88-12-0