前往化源商城

Analytica Chimica Acta 2015-08-19

A molecularly imprinted polymer as the sorptive phase immobilized in a rotating disk extraction device for the determination of diclofenac and mefenamic acid in wastewater.

Valentina Manzo, Karla Ulisse, Inés Rodríguez, Eduardo Pereira, Pablo Richter

文献索引:Anal. Chim. Acta 889 , 130-7, (2015)

全文:HTML全文

摘要

The microextraction of diclofenac and mefenamic acid from water samples was performed by using rotating disk sorptive extraction (RDSE) with molecularly imprinted polymer (MIP) as the sorptive phase. The MIP was synthesized from the monomer 1-vinylimidazol (VI) together with the cross-linker divinylbenzene (DVB) using diphenylamine as the template molecule. Scanning electron microscopy (SEM) analyses of the MIP revealed clusters of spherical particles having a narrow size distribution, with diameters of approximately 1 μm. The optimized extraction conditions involved a disk rotation velocity of 3000 rpm, an extraction time of 120 min, a sample volume of 50 mL, and a sample pH of 2 as well as 25 mg of MIP immobilized in the disk. Desorption of the extracted analytes was performed with 5 mL of methanol for 10 min. Analysis by gas chromatography-mass spectrometry (GC-MS) was carried out after derivatization of the analytes with N-tert-butyldimethylsilyl-N-methyltrifluoroacetamide (MTBSTFA). Nonmolecularly imprinted polymer (NIP) was also synthesized for comparison. It was observed that under the same conditions, MIP extracted significantly more NSAIDs containing diphenylamine (or part of this molecule) in their structure than NIP. Higher significant differences between MIP and NIP were observed for diclofenac, mefenamic acid and paracetamol, clearly indicating the effect of the template on the extraction. Recoveries of the method were between 100 and 112%, with relative standard deviations of 5-6%. The limits of detection were between 60 and 223 ng L(-1). Water samples from a wastewater treatment plant (WWTP) of Santiago de Chile, were found to contain concentrations of these acidic drugs between 1.6 and 4.3 μg L(-1) and between 1.4 and 3.3 μg L(-1) in the influent and effluent, respectively.Copyright © 2015 Elsevier B.V. All rights reserved.

相关化合物

结构式 名称/CAS号 全部文献
氢氧化钠 结构式 氢氧化钠
CAS:1310-73-2
氯化钠 结构式 氯化钠
CAS:7647-14-5
偶氮二异丁腈 结构式 偶氮二异丁腈
CAS:78-67-1
乙醇 结构式 乙醇
CAS:64-17-5
丙酮 结构式 丙酮
CAS:67-64-1
正己烷 结构式 正己烷
CAS:110-54-3
乙腈 结构式 乙腈
CAS:75-05-8
甲基丙烯酸2-(二异丙基氨基)乙酯 结构式 甲基丙烯酸2-(二异丙基氨基)乙酯
CAS:16715-83-6
甲醇 结构式 甲醇
CAS:67-56-1
对乙酰氨基苯酚 结构式 对乙酰氨基苯酚
CAS:103-90-2