American Journal of Physiology - Cell Physiology 2013-04-01

Redox artifacts in electrophysiological recordings.

Jonathan M Berman, Mouhamed S Awayda

Index: Am. J. Physiol. Cell Physiol. 304(7) , C604-13, (2013)

Full Text: HTML

Abstract

Electrophysiological techniques make use of Ag/AgCl electrodes that are in direct contact with cells or bath. In the bath, electrodes are exposed to numerous experimental conditions and chemical reagents that can modify electrode voltage. We examined voltage offsets created in Ag/AgCl electrodes by exposure to redox reagents used in electrophysiological studies. Voltage offsets were measured in reference to an electrode separated from the solution by an agar bridge. The reducing reagents Tris-2-carboxyethly-phosphine, dithiothreitol (DTT), and glutathione, as well as the oxidizing agent H(2)O(2) used at experimentally relevant concentrations reacted with Ag in the electrodes to produce voltage offsets. Chloride ions and strong acids and bases produced offsets at millimolar concentrations. Electrolytic depletion of the AgCl layer, to replicate voltage clamp and sustained use, resulted in increased sensitivity to flow and DTT. Offsets were sensitive to electrode silver purity and to the amount and method of chloride deposition. For example, exposure to 10 μM DTT produced a voltage offset between 10 and 284 mV depending on the chloride deposition method. Currents generated by these offsets are significant and dependent on membrane conductance and by extension the expression of ion channels and may therefore appear to be biological in origin. These data demonstrate a new source of artifacts in electrophysiological recordings that can affect measurements obtained from a variety of experimental techniques from patch clamp to two-electrode voltage clamp.


Related Compounds

Related Articles:

Direct conversion of silver complexes to nanoscale hexagonal columns on a copper alloy for plasmonic applications.

2013-09-21

[Phys. Chem. Chem. Phys. 15(35) , 14611-5, (2013)]

Mixed-valence metal oxide nanoparticles as electrochemical half-cells: substituting the Ag/AgCl of reference electrodes by CeO(2-x) nanoparticles.

2012-12-26

[J. Am. Chem. Soc. 134(51) , 20783-7, (2012)]

Shewanella oneidensis MR-1 chemotaxis proteins and electron-transport chain components essential for congregation near insoluble electron acceptors.

2012-12-01

[Biochem. Soc. Trans. 40(6) , 1167-77, (2012)]

Real time measurement of myocardial oxygen dynamics during cardiac ischemia-reperfusion of rats.

2012-11-21

[Analyst 137(22) , 5312-9, (2012)]

Sensitivities of key parameters in the preparation of silver/silver chloride electrodes used in Harned cell measurements of pH.

2011-01-01

[Sensors (Basel.) 11(8) , 8072-84, (2011)]

More Articles...