Abstract

The retention behavior of a large group of analytes (35) with varied properties (pKa and logP) was studied on eight hydrophilic interaction LC columns with different surfaces, stationary phase chemistries, and types of particles. The acetonitrile content (5-95%), buffer concentration (0.5-200 mM), and pH of the mobile phase (3.8 and 6.8) were evaluated for their effects on the retention behavior. The type of stationary phase had a significant impact on the selectivity and retention time of the tested analytes. Completely different selectivity was observed on the aminopropyl stationary phase. In this study, the influence of the buffer concentration was similar for all tested columns, except for the aminopropyl stationary phase. Increasing the buffer concentration led to decreased retention times for the basic compounds and increased retention times for the acidic compounds, while the inverse behavior was observed on the aminopropyl stationary phase. The selectivity of the individual stationary phases was evaluated at pH 3.8 and 6.8. Much lower selectivity differences between the stationary phases were observed at pH 6.8 than pH 3.8. Bare silica stationary phases were used in the comparison of the particles (fused-core and fully porous particles of 3 and 1.7 μm) and the columns provided by different manufacturers. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.


Related Compounds

Related Articles:

Biomolecular imaging with a C60-SIMS/MALDI dual ion source hybrid mass spectrometer: instrumentation, matrix enhancement, and single cell analysis.

2014-11-01

[J. Am. Soc. Mass Spectrom. 25(11) , 1897-907, (2014)]

Comparative in vitro study on magnetic iron oxide nanoparticles for MRI tracking of adipose tissue-derived progenitor cells.

2014-01-01

[PLoS ONE 9(9) , e108055, (2014)]

Pharmacokinetics, biodistribution, and toxicity of folic acid-coated antiretroviral nanoformulations.

2014-12-01

[Antimicrob. Agents Chemother. 58(12) , 7510-9, (2014)]

Glucose and glycerol concentrations and their tracer enrichment measurements using liquid chromatography tandem mass spectrometry.

2014-10-01

[J. Mass Spectrom. 49(10) , 980-8, (2014)]

Construction and physiochemical characterisation of a multi-composite, potential oral vaccine delivery system (VDS).

2014-07-01

[Int. J. Pharm. 468(1-2) , 264-71, (2014)]

More Articles...