Journal of Separation Science 2015-07-01

Fast determination of octinoxate and oxybenzone uv filters in swimming pool waters by gas chromatography/mass spectrometry after solid-phase microextraction.

Ö Yılmazcan, C Kanakaki, B Izgi, E Rosenberg

Index: J. Sep. Sci. 38 , 2286-97, (2015)

Full Text: HTML

Abstract

A fast gas chromatography/mass spectrometry method was developed and validated for the analysis of the potential endocrine disrupters octinoxate and oxybenzone in swimming pool water samples based on the solvent-free solid-phase microextraction technique. The low-pressure gas chromatography/mass spectrometry method used for the fast identification of UV filter substances was compared to a conventional method in terms of sensitivity and speed. The fast method proposed resulted in 2 min runs, leading to an eightfold decrease in the total analysis time and a sevenfold improvement in detection limits. The main parameters affecting the solid-phase microextraction process were also studied in detail and the optimized conditions were as follows: fiber coating, polyacrylate; extraction mode, direct immersion; extraction temperature, 25°C; sample volume, 5 mL; extraction time 45 min; pH 6.5. Under the optimized conditions, a linear response was obtained in the concentration range of 0.5-25 μg/L with correlation coefficients in the range 0.990-0.999. The limits of detection were 0.17-0.29 μg/L, and the recoveries were 80-83%. Combined method uncertainty was assessed and found to be less than 7% for both analytes for concentrations equal to or higher than 5 μg/L. Pool water samples were analyzed to demonstrate the applicability of the proposed method. Neither octinoxate nor oxybenzone were detected in the swimming pool water samples at concentrations above the respective limits of detection. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.


Related Compounds

Related Articles:

A novel pathway producing dimethylsulphide in bacteria is widespread in soil environments.

2015-01-01

[Nat. Commun. 6 , 6579, (2015)]

Microfluidics-based in situ padlock/rolling circle amplification system for counting single DNA molecules in a cell.

2014-01-01

[Anal. Sci. 30(12) , 1107-12, (2014)]

Combined effects of drying methods, extract concentration, and film thickness on efficacy of antimicrobial chitosan films.

2014-06-01

[J. Food Sci. 79(6) , E1150-8, (2014)]

A salting out system for improving the efficiency of the headspace solid-phase microextraction of short and medium chain free fatty acids.

2015-08-28

[J. Chromatogr. A. 1409 , 282-7, (2015)]

Olfactometry Profiles and Quantitation of Volatile Sulfur Compounds of Swiss Tilsit Cheeses.

2015-09-02

[J. Agric. Food Chem. 63 , 7511-21, (2015)]

More Articles...