e.g. Filippa Pettersson or Cancer Res. 75(6) , 1102-12, (2015) or 10.1002/anie.201600521
Luminescence 2007-01-01
An attempt to design an isoluminol-hydrogen peroxidase-amplified CL that measures intracellularly produced H2O2 in phagocytes: sensitivity for H2O2 is not high enough to allow detection.
A technique was designed for the determination of hydrogen peroxide release. We found, however, that the isoluminol-amplified chemiluminescence technique is a suitable tool for measuring secretion of superoxide but not hydrogen peroxide.Copyright 2007 John Wiley & Sons, Ltd.