前往化源商城

Journal of Chromatography A 1998-06-05

Chromatographic removal of endotoxin from hemoglobin preparations. Effects of solution conditions on endotoxin removal efficiency and protein recovery.

Y Kang, R G Luo

文献索引:J. Chromatogr. A. 809(1-2) , 13-20, (1998)

全文:HTML全文

摘要

In this work, affinity chromatography was used to remove endotoxin from human hemoglobin preparations with a Sterogene Acticlean Etox column. The effects of solution conditions on endotoxin removal efficiency and protein recovery have been investigated. It has been found that cations Na(+) or Ca(2+) reduced endotoxin removal efficiency from 73% (sample prepared with endotoxin-free water) to 31% (sample prepared with 0.15 M NaCl, ionic strength, I = 0.15 M), and from 73% sample prepared with endotoxin-free water) to 9% (sample prepared with 0.05 M CaCl2, ionic strength, I = 0.15 M). It has also been found that the protein recovery was increased from 90% to 99%, respectively.

相关化合物

结构式 名称/CAS号 全部文献
亚铁稳定化血红蛋白 A0 人 结构式 亚铁稳定化血红蛋白 A0 人
CAS:54651-57-9