前往化源商城

Journal of chromatography. A 2015-07-31

Trace analysis of total naphthenic acids in aqueous environmental matrices by liquid chromatography/mass spectrometry-quadrupole time of flight mass spectrometry direct injection.

Pamela Brunswick, Dayue Shang, Graham van Aggelen, Ralph Hindle, L Mark Hewitt, Richard A Frank, Maxine Haberl, Marcus Kim

文献索引:J. Chromatogr. A. 1405 , 49-71, (2015)

全文:HTML全文

摘要

A rapid and sensitive liquid chromatography quadrupole time of flight method has been established for the determination of total naphthenic acid concentrations in aqueous samples. This is the first methodology that has been adopted for routine, high resolution, high throughput analysis of total naphthenic acids at trace levels in unprocessed samples. A calibration range from 0.02 to 1.0μgmL(-1) total Merichem naphthenic acids was validated and demonstrated excellent accuracy (97-111% recovery) and precision (1.9% RSD at 0.02μgmL(-1)). Quantitative validation was also demonstrated in a non-commercial oil sands process water (OSPW) acid extractable organics (AEOs) fraction containing a higher percentage of polycarboxylic acid isomers than the Merichem technical mix. The chromatographic method showed good calibration linearity of ≥0.999 RSQ to 0.005μgmL(-1) total naphthenic acids with a precision <3.1% RSD and a calculated detection limit of 0.0004μgmL(-1) employing Merichem technical mix reference material. The method is well suited to monitoring naturally occurring and industrially derived naphthenic acids (and other AEOs) present in surface and ground waters in the vicinity of mining developments. The advantage of the current method is its direct application to unprocessed environmental samples and to examine natural naphthenic acid isomer profiles. It is noted that where the isomer profile of samples differs from that of the reference material, results should be considered semi-quantitative due to the lack of matching isomer content. The fingerprint profile of naphthenic acids is known to be transitory during aging and the present method has the ability to adapt to monitoring of these changes in naphthenic acid content. The method's total ion scan approach allows for data previously collected to be examined retrospectively for specific analyte mass ions of interest. A list of potential naphthenic acid isomers that decrease in response with aging is proposed and a quantitative assay of an adamantane carboxylic acid is reported. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.

相关化合物

结构式 名称/CAS号 全部文献
乙腈 结构式 乙腈
CAS:75-05-8
甲醇 结构式 甲醇
CAS:67-56-1
氨水 结构式 氨水
CAS:1336-21-6
异丙醇 结构式 异丙醇
CAS:67-63-0
氟化铵 结构式 氟化铵
CAS:12125-01-8
甲醛 结构式 甲醛
CAS:50-00-0
乙酸-12C2 结构式 乙酸-12C2
CAS:1173022-32-6
冰醋酸 结构式 冰醋酸
CAS:64-19-7
1-金刚烷甲酸 结构式 1-金刚烷甲酸
CAS:828-51-3
雄诺龙 结构式 雄诺龙
CAS:521-18-6