前往化源商城

Analytical and Bioanalytical Chemistry 2015-09-01

An improved method for retrospective quantification of sulfur mustard exposure by detection of its albumin adduct using ultra-high pressure liquid chromatography-tandem mass spectrometry.

ChangCai Liu, LongHui Liang, Yu Xiang, HuiLan Yu, ShiKun Zhou, HaiLing Xi, ShiLei Liu, JingQuan Liu

文献索引:Anal. Bioanal. Chem 407 , 7037-46, (2015)

全文:HTML全文

摘要

Sulfur mustard (HD) adduct to human serum albumin (ALB) at Cys-34 residue has become an important and long-term retrospective biomarker of HD exposure. Here, a novel, sensitive, and convenient approach for retrospective quantification of HD concentration exposed to plasma was established by detection of the HD-ALB adduct using ultra-high pressure liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) with a novel non-isotope internal standard (IS). The HD-ALB adduct was isolated from HD-exposed plasma with blue Sepharose. The adduct was digested with proteinase K to form sulfur-hydroxyethylthioethyl ([S-HETE])-Cys-Pro-Phe tripeptide biomarker. The tripeptide adduct could be directly analyzed by UHPLC-MS/MS without an additional solid phase extraction (SPE), which was considered as a critical procedure in previous methods. The easily available 2-chloroethyl ethylsulfide (2-CEES) as HD surrogate was first reported to be used as IS in place of traditional d8-HD for quantification of HD exposure. Furthermore, 2-CEES was also confirmed to be a good IS alternative for quantification of HD exposure by investigation of product ion spectra for their corresponding tripeptide adducts which exhibited identical MS/MS fragmentation behaviors. The method was found to be linear between 1.00 and 250 ng•mL(-1) HD exposure (R(2)>0.9989) with precision of <4.50% relative standard deviation (%RSD), accuracy range between 96.5% and 114%, and a calculated limit of detection (LOD) of 0.532 ng•mL(-1). The lowest reportable limit (LRL) is 1.00 ng•mL(-1), over seven times lower than that of the previous method. The entire method required only 0.1 mL of plasma sample and took under 7 h without special sample preparation equipment. It is proven to be a sensitive, simple, and rugged method, which is easily applied in international laboratories to improve the capabilities for the analysis of biomedical samples related to verification of the Chemical Weapon Convention (CWC).

相关化合物

结构式 名称/CAS号 全部文献
氯化钠 结构式 氯化钠
CAS:7647-14-5
乙腈 结构式 乙腈
CAS:75-05-8
甲酸 结构式 甲酸
CAS:64-18-6
硫磺 结构式 硫磺
CAS:7704-34-9
2-氯乙基乙基硫醚 结构式 2-氯乙基乙基硫醚
CAS:693-07-2
三(羟甲基)氨基甲烷 结构式 三(羟甲基)氨基甲烷
CAS:77-86-1
氯化钠-35cl 结构式 氯化钠-35cl
CAS:20510-55-8
溴甲酚绿 结构式 溴甲酚绿
CAS:76-60-8
磷酸三钠 结构式 磷酸三钠
CAS:7601-54-9