iodipamide structure
|
Common Name | iodipamide | ||
|---|---|---|---|---|
| CAS Number | 606-17-7 | Molecular Weight | 1139.76000 | |
| Density | 2.8g/cm3 | Boiling Point | 908.6ºC at 760 mmHg | |
| Molecular Formula | C20H14I6N2O6 | Melting Point | 306-308ºC (dec.) | |
| MSDS | Chinese USA | Flash Point | 503.3ºC | |
Use of iodipamideIodipamide is a tri-iodinated benzoate derivative and ionic dimeric contrast agent used in diagnostic imaging. |
| Name | 3,3-Adipoyldiiminobis(2,4,6-Triiodobenzoic Acid) |
|---|---|
| Synonym | More Synonyms |
| Description | Iodipamide is a tri-iodinated benzoate derivative and ionic dimeric contrast agent used in diagnostic imaging. |
|---|---|
| Related Catalog | |
| References |
[1]. NCIt |
| Density | 2.8g/cm3 |
|---|---|
| Boiling Point | 908.6ºC at 760 mmHg |
| Melting Point | 306-308ºC (dec.) |
| Molecular Formula | C20H14I6N2O6 |
| Molecular Weight | 1139.76000 |
| Flash Point | 503.3ºC |
| Exact Mass | 1139.51000 |
| PSA | 132.80000 |
| LogP | 6.99420 |
| Index of Refraction | 1.835 |
| Storage condition | 2-8℃ |
CHEMICAL IDENTIFICATION
HEALTH HAZARD DATAACUTE TOXICITY DATA
|
| Personal Protective Equipment | Eyeshields;Gloves;type N95 (US);type P1 (EN143) respirator filter |
|---|---|
| RIDADR | NONH for all modes of transport |
| WGK Germany | 3 |
| RTECS | DG0949500 |
|
~%
iodipamide CAS#:606-17-7 |
| Literature: Chemische Berichte, , vol. 87, p. 651,652 DE936928 , ; US2776241 , ; |
| Precursor 2 | |
|---|---|
| DownStream 0 | |
|
Radiographic features of potential donor livers that precluded donation.
AJR Am. J. Roentgenol. 202(4) , W343-8, (2014) The objective of our study was to catalog the anatomic features shown on preoperative CT that precluded living-donor liver donation.We retrospectively reviewed the records of 159 consecutive candidate... |
|
|
Comparison of multidetector computed tomography angiography and cholangiography performed at 80 and 120 kVp in live liver donors.
J. Comput. Assist. Tomogr. 37(3) , 443-9, (2013) The objective of this study was to compare the radiation exposure and image quality of contrast-enhanced multidetector computed tomography angiography (CTA) and computed tomography cholangiography (CT... |
|
|
Dual-energy, standard and low-kVp contrast-enhanced CT-cholangiography: A comparative analysis of image quality and radiation exposure
Eur. J. Radiol. 81(7) , 1405-12, (2012) Objective Quantitative image quality assessment in terms of image noise (IN), contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) in relation to required radiation dose (RD) for dual-energy... |
| EINECS 210-105-5 |
| MFCD00058983 |
| 3-[[6-(3-carboxy-2,4,6-triiodoanilino)-6-oxohexanoyl]amino]-2,4,6-triiodobenzoic acid |