1-Pyrenebutyric hydrazide structure
|
Common Name | 1-Pyrenebutyric hydrazide | ||
|---|---|---|---|---|
| CAS Number | 55486-13-0 | Molecular Weight | 302.37000 | |
| Density | 1.273g/cm3 | Boiling Point | 588.8ºC at 760 mmHg | |
| Molecular Formula | C20H18N2O | Melting Point | 167-171ºC | |
| MSDS | Chinese USA | Flash Point | 309.9ºC | |
| Symbol |
GHS07 |
Signal Word | Warning | |
| Name | 1-Pyrenebutyric hydrazide |
|---|---|
| Synonym | More Synonyms |
| Density | 1.273g/cm3 |
|---|---|
| Boiling Point | 588.8ºC at 760 mmHg |
| Melting Point | 167-171ºC |
| Molecular Formula | C20H18N2O |
| Molecular Weight | 302.37000 |
| Flash Point | 309.9ºC |
| Exact Mass | 302.14200 |
| PSA | 55.12000 |
| LogP | 4.98780 |
| Index of Refraction | 1.767 |
| Symbol |
GHS07 |
|---|---|
| Signal Word | Warning |
| Hazard Statements | H302-H312-H315-H319-H332-H335 |
| Precautionary Statements | P261-P280-P305 + P351 + P338 |
| Personal Protective Equipment | dust mask type N95 (US);Eyeshields;Gloves |
| Hazard Codes | Xn |
| Risk Phrases | 20/21/22-36/37/38 |
| Safety Phrases | 26-36 |
| RIDADR | NONH for all modes of transport |
| WGK Germany | 3 |
|
~%
1-Pyrenebutyric... CAS#:55486-13-0 |
| Literature: Organic and Biomolecular Chemistry, , vol. 5, # 11 p. 1771 - 1775 |
|
~%
1-Pyrenebutyric... CAS#:55486-13-0 |
| Literature: Organic and Biomolecular Chemistry, , vol. 5, # 11 p. 1771 - 1775 |
| Precursor 2 | |
|---|---|
| DownStream 0 | |
|
Labeling of the glycoprotein subunit of (Na,K)ATPase with fluorescent probes.
Biochemistry 24 , 322, (1985) Sodium plus potassium activated adenosinetriphosphatase [(Na,K)ATPase] is composed of a catalytic subunit (alpha) and a glycoprotein subunit (beta) of unknown function. A method has been developed to ... |
|
|
On-target derivatization of keratan sulfate oligosaccharides with pyrenebutyric acid hydrazide for MALDI-TOF/TOF-MS.
J. Mass Spectrom. 43(6) , 765-72, (2008) In the present work, a rapid and novel method of on-target plate derivatization of keratan sulfate (KS) oligosaccharides for subsequent analysis by matrix-assisted laser desorption and ionization (MAL... |
|
|
Liquid chromatographic determination of microcystins in water samples following pre-column excimer fluorescence derivatization with 4-(1-pyrene)butanoic acid hydrazide.
Anal. Chim. Acta 755 , 93-9, (2012) A method to measure the concentrations of microcystins (MCs) in water samples has been developed by incorporating pre-column fluorescence derivatization and liquid chromatography (LC). A solid-phase e... |
| 4-pyren-1-ylbutanehydrazide |