Journal of Colloid and Interface Science 2012-01-01

A general method to determine ionization constants of responsive polymer thin films.

Hui Wang, Irene H Lee, Mingdi Yan, Hui Wang, Irene H Lee, Mingdi Yan, Hui Wang, Irene H. Lee, Mingdi Yan

Index: J. Colloid. Interface Sci. 365(1) , 178-83, (2012)

Full Text: HTML

Abstract

A general method has been developed to determine the ionization constants of polymer thin films based on the stimuli-responsiveness of the polymer. Robust polymer films were fabricated on silicon wafers and gold slides using perfluorophenyl azide (PFPA) as the coupling agent. The ionization constants were measured by a number of techniques including ellipsometry, dynamic contact angle goniometry, and surface plasmon resonance imaging (SPRi). Using poly(4-vinylpyridine) (P4VP) as the model system, P4VP thin films were fabricated and the ionization constants of the films were measured taking advantage of the pH responsive property of the polymer. The pK(a) determined by ellipsometry, ~4.0, reflects the swelling of the polymer film in response to pH. The pK(a) value calculated from the dynamic contact angle measurements, ~5.0, relies on the change in hydrophilicity/hydrophobicity of the films as the polymer undergoes protonation/deprotonation. The pK(a) value measured by SPRi, ~4.9, monitors in situ the change of refractive index of the polymer thin film as it swells upon protonation. This was the first example where SPRi was used to measure the ionization constants of polymers.Copyright © 2011 Elsevier Inc. All rights reserved.


Related Compounds

Related Articles:

Interpolymer complexes and polymer compatibility.

2012-11-23

[Macromol. Rapid Commun. 33(22) , 1933-7, (2012)]

Encapsulation of TiO2 nanoparticles with poly(4-vinylpyridine) using surface functionalized thiol-lactam initiated radical polymerization.

2013-05-01

[J. Nanosci. Nanotechnol. 13(5) , 3546-9, (2013)]

Layer-by-layer assembly and characterization of multilayers of a manganese porphyrin linked poly(4-vinylpyridinium) derivative and poly(styrenesulfonic acid-o-maleic) acid.

2011-08-16

[Langmuir 27(16) , 9880-9, (2011)]

Comparative study of the uses of poly(4-vinylpyridine) and poly(diallyldimethylammonium) chloride for the removal of perchlorate from aqueous solution by polyelectrolyte-enhanced ultrafiltration.

2011-01-01

[Water Res. 45(3) , 1387-93, (2011)]

Initiated chemical vapor deposition-based method for patterning polymer and metal microstructures on curved substrates.

2012-12-18

[Adv. Mater. 24(48) , 6445-50, (2012)]

More Articles...