Journal of Agricultural and Food Chemistry 2001-05-01

Rapid and specific detection of hydroxyl radical using an ultraweak chemiluminescence analyzer and a low-level chemiluminescence emitter: application to hydroxyl radical-scavenging ability of aqueous extracts of Food constituents.

C H Tsai, A Stern, J F Chiou, C L Chern, T Z Liu

Index: J. Agric. Food Chem. 49(5) , 2137-41, (2001)

Full Text: HTML

Abstract

With the availability of an ultraweak chemiluminescence analyzer, it is possible to monitor the production of a specific oxygen-derived reactive species, such as hydroxyl radical ((*)OH), whenever a suitable chemiluminescent probe is obtainable. Reported herein is the development of a rapid and specific method for detecting (*)OH production using a specific probe, indoxyl-beta-glucuronide (IBG), a low-level chemiluminescence emitter. Using the Fenton reagent as a source of (*)OH, it was shown that IBG could elicit a very strong intensity of chemiluminescence (CL) (16200 +/- 200 photon counts/s). Conversely, IBG was shown to be insensitive to either superoxide radical or hydrogen peroxide with their CL intensities nearly close to the background values (25 +/- 5 and 180 +/- 20 photon counts/s, respectively). Furthermore, it was also shown that this IBG-based CL production could be effectively quenched by the addition of (*)OH scavengers such as sodium salicylate, dimethyl sulfoxide, and penicillamine to the assay system. Taken together, these data indicate that IBG is a specific CL probe suitable for monitoring the production of (*)OH. This system demonstrated inhibitory activities of various aqueous extracts of food constituents on the CL of hydroxyl radicals generated by Fenton's reagents with the order of scavenging efficiencies being Prunus mume > Cordyceps sinensin > Lilium lancifolium > Astragalus membranceus.


Related Compounds

Related Articles:

Rapid detection of Escherichia coli in urine samples by a new chromogenic beta-glucuronidase assay.

1989-04-01

[J. Clin. Microbiol. 27 , 778-779, (1989)]

Accumulation of indoxyl-beta-D-glucuronide in uremic serum: suppression of its production by oral sorbent and efficient removal by hemodialysis.

1996-01-01

[Nephron 74(1) , 72-8, (1996)]

[Evaluation of a new disk containing indoxyl-beta-D-glucuronide for rapid identification of Escherichia coli].

1996-09-01

[Rinsho Byori. 44(9) , 895-8, (1996)]

Comparison of the recoveries of Escherichia coli and total coliforms from drinking water by the MI agar method and the U.S. Environmental Protection Agency-approved membrane filter method.

1996-01-01

[Appl. Environ. Microbiol. 62(1) , 203-8, (1996)]

Indoxyl-beta-D-glucuronide, the primary emitter of low-level chemiluminescence in plasma of hemodialysis patients.

1994-08-01

[Clin. Chem. 40(8) , 1580-6, (1994)]

More Articles...