Microcirculation 2013-02-01

Polycystic kidneys have decreased vascular density: a micro-CT study.

Rende Xu, Federico Franchi, Brent Miller, John A Crane, Karen M Peterson, Peter J Psaltis, Peter C Harris, Lilach O Lerman, Martin Rodriguez-Porcel

Index: Microcirculation 20(2) , 183-9, (2013)

Full Text: HTML

Abstract

Polycystic kidney disease (PKD) is a common cause of end-stage renal failure and many of these patients suffer vascular dysfunction and hypertension. It remains unclear whether PKD is associated with abnormal microvascular structure. Thus, this study examined the renovascular structure in PKD.PKD rats (PCK model) and controls were studied at 10 weeks of age, and mean arterial pressure (MAP), renal blood flow, and creatinine clearance were measured. Microvascular architecture and cyst number and volume were assessed using micro-computed tomography, and angiogenic pathways evaluated.Compared with controls, PKD animals had an increase in MAP (126.4 ± 4.0 vs. 126.2 ± 2.7 mmHg) and decreased clearance of creatinine (0.39 ± 0.09 vs. 0.30 ± 0.05 mL/min), associated with a decrease in microvascular density, both in the cortex (256 ± 22 vs. 136 ± 20 vessels per cm2) and medullar (114 ± 14 vs. 50 ± 9 vessels/cm2) and an increase in the average diameter of glomeruli (104.14 ± 2.94 vs. 125.76 ± 9.06 mm). PKD animals had increased fibrosis (2.2 ± 0.2 fold vs. control) and a decrease in the cortical expression in hypoxia inducible factor 1-α and vascular endothelial growth factor.PKD animals have impaired renal vascular architecture, which can have significant functional consequences. The PKD microvasculature could represent a therapeutic target to decrease the impact of this disease.© 2012 John Wiley & Sons Ltd.


Related Compounds

Related Articles:

Analytical expression of non-steady-state concentrations and current pertaining to compounds present in the enzyme membrane of biosensor.

2011-05-05

[J. Phys. Chem. A 115(17) , 4299-306, (2011)]

Immobilization of creatininase, creatinase and sarcosine oxidase on iron oxide nanoparticles/chitosan-g-polyaniline modified Pt electrode for detection of creatinine.

2012-04-05

[Enzyme Microb. Technol. 50(4-5) , 247-54, (2012)]

Amperometric creatinine biosensor based on covalently coimmobilized enzymes onto carboxylated multiwalled carbon nanotubes/polyaniline composite film.

2011-12-15

[Anal. Biochem. 419(2) , 277-83, (2011)]

One-chip biosensor for simultaneous disease marker/calibration substance measurement in human urine by electrochemical surface plasmon resonance method.

2010-12-15

[Biosens. Bioelectron. 26(4) , 1536-42, (2010)]

Simultaneous detection of creatine and creatinine using a sequential injection analysis/biosensor system.

2006-01-01

[Prep Biochem Biotechnol. 36(4) , 287-96, (2006)]

More Articles...