Determination of the enantiomers of zopiclone and its two chiral metabolites in urine using an automated coupled achiral-chiral chromatographic system.
C Fernandez, F Gimenez, B Baune, V Maradeix, A Thuillier, R Farinotti
Index: J. Chromatogr. A. 617(2) , 271-8, (1993)
Full Text: HTML
Abstract
The enantiomers of zopiclone and its two chiral N-desmethyl and N-oxide metabolites were determined in urine using a coupled achiral-chiral liquid chromatographic method. After liquid-liquid extraction, zopiclone and its two metabolites were quantified on a cyanopropyl column. After fluorimetric detection on the achiral system, the eluent was switched through a silica precolumn in order to trap and concentrate the analytes. Each fraction was then backflushed separately onto a carbamate cellulose chiral stationary phase in order to determine the enantiomeric ratios. The coupled system was automated with an autosampler and a switching valve programmed by an integrator. The method was validated, and a first trial was performed on urine samples of a volunteer treated with 15 mg of racemic zopiclone.
Related Compounds
Related Articles:
Capillary electrophoretic enantioselective determination of zopiclone and its impurities.
2012-06-01
[Electrophoresis 33(11) , 1606-12, (2012)]
[J. Chromatogr. A. 417(1) , 151-8, (1987)]
Pharmacokinetics of zopiclone and its enantiomers in Caucasian young healthy volunteers.
1993-01-01
[Drug Metab. Dispos. 21(6) , 1125-8, (1993)]
Two cases of methemoglobinemia following zopiclone ingestion.
2008-02-01
[Clin. Toxicol. (Phila.) 46(2) , 167-70, (2008)]
2008-03-15
[J. Chromatogr. B. Analyt. Technol. Biomed. Life Sci. 864(1-2) , 137-48, (2008)]