Clinical and Experimental Medicine 2006-10-01

Fluctuations in fasting blood glucose and serum fructosamine in pregnant women monitored on successive antenatal visits.

H A Khan, S H Sobki, A S Alhomida

Index: Clin. Exp. Med. 6(3) , 134-7, (2006)

Full Text: HTML

Abstract

Fasting blood glucose (FBG) and serum fructosamine are simple and commonly used tests for monitoring diabetes mellitus. Unfortunately, both these parameters are associated with high error rates and therefore used with caution in high-risk populations. Setting high cut-off values for these parameters increases the sensitivity but at the cost of poor specificity (more false positives). Continued efforts have been made to evaluate the efficacy of FBG and fructosamine, singly or in combination, in avoiding a large number of unnecessary oral glucose tolerance tests (OGTT). Therefore, to better understand their time-course trends, we analysed FBG and c-fructosamine in 211 blood samples from 51 Saudi pregnant women during their multiple (> or =3) antenatal visits. The mean+/-standard deviation of FBG and c-fructosamine were 5.22+/-1.07 and 2.22+/-0.25 mmol/l respectively with a significant correlation between their individual values. Using the FBG cut-off >5.3 mmol/l, 19 subjects were classified as hyperglycaemic; this frequency was reduced to 1 when a FBG cut-off of >7.0 mmol/l was used. Combined values of FBG (>5.3 mmol/l) and c-fructosamine (>2.5 mmol/l) filtered 6 high-risk subjects with a prediction of gestational diabetes mellitus (GDM). Analysis of variance revealed high within-group variance for FBG. These fluctuations were also confirmed by higher coefficient of variations (CVs) for FBG (13.27%) as compared to c-fructosamine (5.49%). The CVs of FBG were not correlated with those of corresponding CVs of c-fructosamine (R = 0.007, P = 0.962), indicating that the fluctuations in FBG were independent of fluctuations in c-fructosamine. These findings clearly suggest that the paired values of FBG and c-fructosamine would be more advantageous than their individual values in filtering high-risk patients on whom OGTT should be performed.


Related Compounds

Related Articles:

Development of a novel magnetic molecularly imprinted polymer coating using porous zeolite imidazolate framework-8 coated magnetic iron oxide as carrier for automated solid phase microextraction of estrogens in fish and pork samples.

2014-10-01

[J. Chromatogr. A. 1365 , 35-44, (2014)]

Highly sensitive Fe₃O₄ nanobeads/graphene-based molecularly imprinted electrochemical sensor for 17β-estradiol in water.

2015-07-16

[Anal. Chim. Acta 884 , 106-13, (2015)]

Water-compatible magnetic imprinted nanoparticles served as solid-phase extraction sorbents for selective determination of trace 17beta-estradiol in environmental water samples by liquid chromatography.

2015-05-29

[J. Chromatogr. A. 1396 , 7-16, (2015)]

Cheminformatics analysis of assertions mined from literature that describe drug-induced liver injury in different species.

2010-01-01

[Chem. Res. Toxicol. 23 , 171-83, (2010)]

Calculating virtual log P in the alkane/water system (log P(N)(alk)) and its derived parameters deltalog P(N)(oct-alk) and log D(pH)(alk).

2005-05-05

[J. Med. Chem. 48 , 3269-79, (2005)]

More Articles...