Journal of Mass Spectrometry 2005-04-01

Development and validation of a liquid chromatographic/electrospray ionization mass spectrometric method for the quantitation of prazepam and its main metabolites in human plasma.

Paraskevi Valavani, Julia Atta-Politou, Irene Panderi

Index: J. Mass Spectrom. 40(4) , 516-26, (2005)

Full Text: HTML

Abstract

A method was developed and fully validated for the quantitation of prazepam and its major metabolites, oxazepam and nordiazepam, in human plasma. Sample pretreatment was achieved by solid-phase extraction using Oasis HLB cartridges. The extracts were analysed by high-performance liquid chromatography (HPLC) coupled with single-quadrupole mass spectrometry (MS) with an electrospray ionization interface. The MS system was operated in the selected ion monitoring mode. HPLC was performed isocratically on a reversed-phase XTerra MS C18 analytical column (150 x 3.0 mm i.d., particle size 5 microm). Diazepam was used as the internal standard for quantitation. The assay was linear over a concentration range of 5.0-1000 ng ml(-1) for all compounds analyzed. The limit of quantitation was 5 ng ml(-1) for all compounds. Quality control samples (5, 10, 300 and 1000 ng ml(-1)) in five replicates from three different runs of analysis demonstrated an intra-assay precision (CV) of < or = 9.1%, an inter-assay precision of < or = 6.0% and an overall accuracy (relative error) of < 4.6%. The method can be used to quantify prazepam and its metabolites in human plasma covering a variety of pharmacokinetic or bioequivalence studies.Copyright 2005 John Wiley & Sons, Ltd.


Related Compounds

Related Articles:

Cleaning up blood samples using a modified "QuEChERS" procedure for the determination of drugs of abuse and benzodiazepines by UPLC-MSMS(☆).

2014-10-01

[Forensic Sci. Int. 243 , 99-106, (2014)]

Simple and sensitive screening and quantitative determination of 88 psychoactive drugs and their metabolites in blood through LC–MS/MS: Application on postmortem samples

2014-11-01

[J. Chromatogr. B. Analyt. Technol. Biomed. Life Sci. 970 , 1-7, (2014)]

Dynamic high performance liquid chromatography on chiral stationary phases. Low temperature separation of the interconverting enantiomers of diazepam, flunitrazepam, prazepam and tetrazepam.

2014-10-10

[J. Chromatogr. A. 1363 , 144-9, (2014)]

A salt-free isocratic high-pressure liquid chromatographic method for the quantitation of benzodiazepines in serum.

1993-06-01

[Clin. Biochem. 26(3) , 165-71, (1993)]

Kinetic study on the degradation of prazepam in acidic aqueous solutions by high-performance liquid chromatography and fourth-order derivative ultraviolet spectrophotometry.

1998-08-01

[J. Pharm. Biomed. Anal. 17(4-5) , 739-50, (1998)]

More Articles...