Biosensors and Bioelectronics 2015-05-15

In vivo continuous and simultaneous monitoring of brain energy substrates with a multiplex amperometric enzyme-based biosensor device.

C A Cordeiro, M G de Vries, W Ngabi, P E Oomen, T I F H Cremers, B H C Westerink

Index: Biosens. Bioelectron. 67 , 677-86, (2015)

Full Text: HTML

Abstract

Enzyme-based amperometric biosensors are widely used for monitoring key biomarkers. In experimental neuroscience there is a growing interest in in vivo continuous and simultaneous monitoring of metabolism-related biomarkers, like glucose, lactate and pyruvate. The use of multiplex biosensors will provide better understanding of brain energy metabolism and its role in neuropathologies such as diabetes, ischemia, and epilepsy. We have developed and characterized an implantable multiplex microbiosensor device (MBD) for simultaneous and continuous in vivo monitoring of glucose, lactate, and pyruvate. First, we developed and characterized amperometric microbiosensors for monitoring lactate and pyruvate. In vitro evaluation allowed us to choose the most suitable biosensors for incorporation into the MBD, along with glucose and background biosensors. Fully assembled MBDs were characterized in vitro. The calculated performance parameters (LOD, LR, LRS, IMAX and appKM) showed that the multiplex MBD was highly selective and sensitive (LRS≥100 nA/mM) for each analyte and within an adequate range for in vivo application. Finally, MBDs were implanted in the mPFC of anesthetized adult male Wistar rats for in vivo evaluation. Following an equilibration period, baseline brain levels of glucose (1.3±0.2 mM), lactate (1.5±0.4 mM) and pyruvate (0.3±0.1 mM) were established. Subsequently, the MBDs recorded the responses of the animals when submitted to hyperglycemic (40% glucose i.v.) and hypoglycemic (5 U/kg insulin i.v.) challenges. Afterwards, MBDs were recalibrated to convert electrochemical readings into accurate substrate concentrations and to assess biofouling. The presented MBD can monitor simultaneously multiple biomarkers in vivo.Copyright © 2014 Elsevier B.V. All rights reserved.


Related Compounds

Related Articles:

Driving cartilage formation in high-density human adipose-derived stem cell aggregate and sheet constructs without exogenous growth factor delivery.

2014-12-01

[Tissue Eng. Part A 20(23-24) , 3163-75, (2014)]

A short splice form of Xin-actin binding repeat containing 2 (XIRP2) lacking the Xin repeats is required for maintenance of stereocilia morphology and hearing function.

2015-02-04

[J. Neurosci. 35(5) , 1999-2014, (2015)]

Oversulfated heparins with low anticoagulant activity are strong and fast inhibitors of hepcidin expression in vitro and in vivo.

2014-12-01

[Biochem. Pharmacol. 92(3) , 467-75, (2014)]

Establishment and characterization of an air-liquid canine corneal organ culture model to study acute herpes keratitis.

2014-12-01

[J. Virol. 88(23) , 13669-77, (2014)]

Hypoxia reduces MAX expression in endothelial cells by unproductive splicing.

2014-12-20

[FEBS Lett. 588(24) , 4784-90, (2014)]

More Articles...