Journal of chromatography. A 2015-08-28

Selective extraction and analysis of catecholamines in rat blood microdialysate by polymeric ionic liquid-diphenylboric acid-packed capillary column and fast separation in high-performance liquid chromatography-electrochemical detector.

Xinguang Zhou, Anwei Zhu, Guoyue Shi

Index: J. Chromatogr. A. 1409 , 125-31, (2015)

Full Text: HTML

Abstract

Concentration of blood catecholamines (CAs) is linked to a host of cardiovascular diseases, including hypertension and stenocardia. The matrix interferences and low concentration require tedious sample pretreatment methods before quantitative analysis by the gold standard method of high-performance liquid chromatography-electrochemical detector (HPLC-ECD). Solid phase extraction (SPE) has been widely used as the pretreatment technique. Here, a facile polymeric ionic liquid (PIL)-diphenylboric acid (DPBA)-packed capillary column was prepared to selectively extract dopamine (DA), noradrenaline (NE) and epinephrine (E) prior to their quantitative analysis by a fast separation in HPLC-ECD method, while microdialysis sampling method was applied to get the analysis sample. Parameters that influenced desorption efficiency, such as pH, salt concentration, acetonitrile content and wash time, were examined and optimized. The proposed method, combining microdialysis sampling technique, SPE and HPLC-ECD system, was successfully applied to detect CAs in rat blood microdialysate with high sensitivity and selectivity in small sample volumes (5-40μl) and a short analysis time (8min), yielding good reproducibility (RSD 6.5-7.7%) and spiked recovery (91-104.4%). Copyright © 2015 Elsevier B.V. All rights reserved.


Related Compounds

Related Articles:

Injectable Peptide Decorated Functional Nanofibrous Hollow Microspheres to Direct Stem Cell Differentiation and Tissue Regeneration.

2015-06-01

[Adv. Funct. Mater. 25(3) , 350-360, (2015)]

An Optically Driven Bistable Janus Rotor with Patterned Metal Coatings.

2015-11-24

[ACS Nano 9 , 10844-51, (2015)]

Organic monolith frits encased in polyether ether ketone tubing with improved durability for liquid chromatography.

2015-09-01

[J. Sep. Sci. 38 , 2938-44, (2015)]

Controlled Endolysosomal Release of Agents by pH-responsive Polymer Blend Particles.

2015-07-01

[Pharm. Res. 32 , 2280-91, (2015)]

Polyethylene Glycol Coatings on Plastic Substrates for Chemically Defined Stem Cell Culture.

2015-07-15

[Adv. Healthc. Mater. 4 , 1555-64, (2015)]

More Articles...