Journal of Cardiovascular Computed Tomography 2015-01-01

Low contrast and radiation dose coronary CT angiography using a 320-row system and a refined contrast injection and timing method.

Seitaro Oda, Daisuke Utsunomiya, Hideaki Yuki, Noriyuki Kai, Masahiro Hatemura, Yoshinori Funama, Masafumi Kidoh, Morikatsu Yoshida, Tomohiro Namimoto, Yasuyuki Yamashita

Index: J. Cardiovasc. Comput. Tomogr. 9(1) , 19-27, (2015)

Full Text: HTML

Abstract

Among CT scanners, 320-row instruments feature decreased photon energy and yield strong contrast enhancement. Consequently, the contrast medium (CM) dose can be reduced. The results of low-tube-voltage coronary CT angiography (CCTA) performed on 320-row scanners have not been adequately assessed.We evaluated the effects of a low-contrast-dose protocol on the image quality of CCTA using 80 kVp tube voltage, iterative reconstruction (IR), and a 320-row scanner.We randomly assigned 90 patients (mean body weight, 56.5 ± 11.0 kg) to 1 of 3 CCTA protocols. Under protocol A, 30 were scanned using a conventional 120-kVp protocol and a standard CM dose (280 mg iodine/kg body weight [mgI/kg]). Another 30 underwent scanning at 80 kVp with a 25% CM dose reduction (210 mgI/kg; protocol B). Under protocol C, the remaining 30 patients were scanned at 80 kVp with a 50% CM dose reduction (140 mgI/kg). The 120 and 80 kVp images were processed with IR. Images obtained under the 3 protocols were subjected to quantitative and qualitative analysis.The amount of CM used in protocol A, B, and C was 43.6 ± 10.1, 30.3 ± 4.4, and 21.0 ± 4.0 mL, respectively. Mean CT attenuation of the coronary arteries tended to be higher under protocol B than the other 2 protocols. The contrast-to-noise ratio was significantly higher under protocol B. The mean visual scores were significantly higher for protocols A and B than protocol C. The mean effective radiation dose was significantly lower under the 80-kVp protocol.With a 320-row scanner and our refined CM injection and timing protocol, it is technically feasible to obtain sufficient vascular enhancement with a reduction in the CM and/or radiation dose at 80-kVp CCTA with IR.Copyright © 2015 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.


Related Compounds

Related Articles:

Aptamer-based polyvalent ligands for regulated cell attachment on the hydrogel surface.

2015-04-13

[Biomacromolecules 16(4) , 1382-9, (2015)]

Assembly and structure of Lys33-linked polyubiquitin reveals distinct conformations.

2015-04-15

[Biochem. J. 467(2) , 345-52, (2015)]

Small-molecule inhibitors of ERK-mediated immediate early gene expression and proliferation of melanoma cells expressing mutated BRaf.

2015-05-01

[Biochem. J. 467(3) , 425-38, (2015)]

Fine mapping and characterization of the L-polymerase-binding domain of the respiratory syncytial virus phosphoprotein.

2015-04-01

[J. Virol. 89(8) , 4421-33, (2015)]

DNase II-dependent DNA digestion is required for DNA sensing by TLR9.

2015-01-01

[Nat. Commun. 6 , 5853, (2015)]

More Articles...