Stefan Schmid, Matthias C. Jecklin, Renato Zenobi
文献索引:J. Chromatogr. A. 1218 , 3704-10, (2011)
全文:HTML全文
Electrosonic spray ionization (ESSI) has been studied as an interface between high-performance liquid chromatography (HPLC) and mass spectrometry (MS), using sample flow rates up to 3.0 ml min −1. This ionization interface was compared with pneumatically assisted electrospray ionization (ESI) using mass spectrometry for detection. For experiments that did not involve direct comparison of different flow rates, the ESI experiments were performed using post column splitting to work at optimal conditions. ESSI allows the interfacing of conventional or high-resolution liquid chromatography (LC) methods to mass spectrometry without post column splitting. High sample flow rates could be handled without a significant loss of signal intensity using a nebulization gas flow rate of 5.5 L min −1. Since ESI needs to be operated with lower sample flow rates, it is limited to micro/nano LC systems, or post column splitting must be used. In particular, nano LC systems have to be treated with great care and require constant maintenance. When using post-column splitting, the increased diffusion can become a problem especially when using systems with very small void volumes. In all experiments ESSI showed better signal intensities than a commercially available, pneumatically assisted ESI source. ESSI does not require heating of the nebulizer gas, which should help to preserve the original structure of thermally unstable molecules. Therefore, ESSI is presented as an alternative to the commercially available heated ESI sources of AB SCIEX, Thermo Fischer, Agilent and Waters. The observed LC-ESSI-MS ion chromatograms are shown to be very stable even when using flow rates higher than 1.0 ml min −1, which could be very suitable for ultra high performance LC, where sample flow rates up to 2.0 mL min −1 with backpressures up to 1200 bar are used. Also, a difference in the relative intensities of singly and doubly protonated peptide monomers and dimers was observed between the two ionization methods. The coefficients of determination for the calibration of instrument response for Val–Tyr–Val and Met-Enkephalin showed excellent linearity over a wide concentration range (0.1–100 μM), while ESI results were only linear over a much smaller range (0.1–20 μM). The observed behavior is thought to be caused by insufficient ionization efficiency of solutions above ∼20 μM by ESI, exemplifying the robustness of ESSI as an interface between LC and MS.
结构式 | 名称/CAS号 | 分子式 | 全部文献 |
---|---|---|---|
![]() |
[5-Methionine]Enkephalin,Enkephalin M
CAS:82362-17-2 |
C29H41N5O10S |
Analysis of peptides and protein digests by reversed phase h...
2015-05-04 [Anal. Chim. Acta 872 , 84-94, (2015)] |
Methionine enkephalin: a new cytokine--human studies.
1997-02-01 [Clin. Immunol. Immunopathol. 82 , 93-101, (1997)] |
Proteases and the emerging role of protease inhibitors in pr...
1994-12-01 [FASEB J. 8 , 1269-1278, (1994)] |
The cloned mu, delta and kappa receptors and their endogenou...
1995-11-27 [Brain Res. 700 , 89-98, (1995)] |
Identification and characterization of opioid growth factor ...
2000-01-01 [J. Mol. Med. 5 , 77-84, (2000)] |
首页 |
期刊大全 |
MSDS查询 |
化工产品分类 |
生物活性化合物 |
关于我们 |
免责声明:知识产权问题请联系 service1@chemsrc.com
Copyright © 2024 ChemSrc All Rights Reserved