前往化源商城

Chirality 2007-01-01

Stereoselective determination of benalaxyl in plasma by chiral high-performance liquid chromatography with diode array detector and application to pharmacokinetic study in rabbits.

Jing Qiu, Qiuxia Wang, Wentao Zhu, Guifang Jia, Xinquan Wang, Zhiqiang Zhou

文献索引:Chirality 19(1) , 51-5, (2007)

全文:HTML全文

摘要

A chiral high-performance liquid chromatography method with diode array detector was developed and validated for stereoselective determination of benalaxyl (BX) in rabbit plasma. Good separation was achieved at 20 degrees C using cellulose tris-(3,5-dimethylphenylcarbamate) as chiral stationary phase, a mixture of n-hexane and 2-propanol (97:3) as mobile phase at a flow rate of 1.0 ml/min. The assay method was linear over a range of concentrations (0.25-25 microg/ml) in plasma and the mean recovery was greater than 90% for both enantiomers. The limits of quantification and detection for both enantiomers in plasma were 0.25 and 0.1 microg/ml, respectively. Intra- and interday relative standard deviations (RSDs) did not exceed 10% for three-tested concentrations. The method was successfully applied to pharmacokinetic studies of BX enantiomers in rabbits. The result suggested that the pharmacokinetics of BX enantiomers was stereoselective in rabbits.(c) 2006 Wiley-Liss, Inc.

相关化合物

结构式 名称/CAS号 全部文献
R-N-(2,6-二甲基苯基)-N-(苯乙酰基)丙氨酸甲酯 结构式 R-N-(2,6-二甲基苯基)-N-(苯乙酰基)丙氨酸甲酯
CAS:98243-83-5
苯霜灵 结构式 苯霜灵
CAS:71626-11-4