前往化源商城

Journal of chromatography. B, Biomedical sciences and applications 1997-08-29

Determination of diazolidinyl urea in a topical cream by high-performance liquid chromatography.

R O Williams, V Mahaguna, M Sriwongjanya

文献索引:J. Chromatogr. B. Biomed. Sci. Appl. 696(2) , 303-6, (1997)

全文:HTML全文

摘要

A high-performance liquid chromatographic method for the determination of diazolidinyl urea (DU) in a cream formulation is described. The aqueous phase of the emulsion was separated by centrifugation, removed, filtered, diluted and applied onto the HPLC system. DU was detected by ultraviolet absorption at a wavelength of 214 nm. The calibration curve was linear over the range of 79-553 micrograms/ml, and identical when determined on consecutive days. The relative standard deviation for repeat determinations was less than 0.5%. Recoveries were 97.74-101.72%. This analytical method is useful for quantitation of DU in cream formulations.

相关化合物

结构式 名称/CAS号 全部文献
重氮烷基脲 结构式 重氮烷基脲
CAS:78491-02-8