前往化源商城

Talanta 2011-12-15

Simultaneous injection effective mixing analysis system for the determination of direct bilirubin in urinary samples.

Kraingkrai Ponhong, Norio Teshima, Kate Grudpan, Shoji Motomizu, Tadao Sakai

文献索引:Talanta 87 , 113-7, (2011)

全文:HTML全文

摘要

A novel simultaneous injection effective mixing analysis system (SIEMA) for determination of direct bilirubin in urine sample was developed. Bilirubin reacts with diazotized sulfanilic acid in the presence of n-octyl-β-d-thioglucoside (OTG) as a solubilizing agent to form OTG-azobilirubin. The flow and chemical variables were investigated. A linear calibration graph for direct bilirubin was obtained over the range of 0-1.0 mg L(-1) (r(2)=0.994) with the limit of detection (3σ) of 4.7 μg L(-1), and the relative standard deviation (RSD) being 1.9% (n=11, 0.5 mg L(-1) of direct bilirubin). The results in healthy adult urine obtained by the proposed approach were found in good agreement with those obtained by the batch-wise diazo method.Copyright © 2011 Elsevier B.V. All rights reserved.

相关化合物

结构式 名称/CAS号 全部文献
辛基-β-D-硫代吡喃葡萄糖苷 结构式 辛基-β-D-硫代吡喃葡萄糖苷
CAS:85618-21-9