前往化源商城

Journal of Environmental Sciences 2012-01-01

A screen-printed, amperometric biosensor for the determination of organophosphorus pesticides in water samples.

Junfeng Dou, Fuqiang Fan, Aizhong Ding, Lirong Cheng, Raju Sekar, Hongting Wang, Shuairan Li

文献索引:J. Environ. Sci. (China) 24(5) , 956-62, (2012)

全文:HTML全文

摘要

An amperometric biosensor based on screen-printed electrodes (SPEs) was developed for the determination of organophosphorus pesticides in water samples. The extent of acetylcholinesterase (AChE) deactivation was determined and quantified for pesticide concentrations in water samples. An enzyme immobilization adsorption procedure and polyacrylamide gel matrix polymerization were used for fabrication of the biosensor, with minimal losses in enzyme activity. The optimal conditions for enzyme catalytic reaction on the SPEs surfaces were acetylthiocholine chloride (ATChCl) concentration of 5 mmol/L, pH 7 and reaction time of 4 min. The detection limits for three organophosphorus pesticides (dichlorvos, monocrotophs and parathion) were in the range of 4 to 7 microg/L when an AChE amount of 0.1 U was used for immobilization.

相关化合物

结构式 名称/CAS号 全部文献
巴拉松 结构式 巴拉松
CAS:56-38-2
久效磷 结构式 久效磷
CAS:6923-22-4
敌敌畏 结构式 敌敌畏
CAS:62-73-7