前往化源商城

Rapid Communications in Mass Spectrometry 2015-07-15

Comparison of gas chromatography/isotope ratio mass spectrometry and liquid chromatography/isotope ratio mass spectrometry for carbon stable-isotope analysis of carbohydrates.

Tanja C W Moerdijk-Poortvliet, Henk Schierbeek, Marco Houtekamer, Tom van Engeland, Delphine Derrien, Lucas J Stal, Henricus T S Boschker

文献索引:Rapid Commun. Mass Spectrom. 29 , 1205-14, (2015)

全文:HTML全文

摘要

We compared gas chromatography/isotope ratio mass spectrometry (GC/IRMS) and liquid chromatography/isotope ratio mass spectrometry (LC/IRMS) for the measurement of δ(13)C values in carbohydrates. Contrary to GC/IRMS, no derivatisation is needed for LC/IRMS analysis of carbohydrates. Hence, although LC/IRMS is expected to be more accurate and precise, no direct comparison has been reported.GC/IRMS with the aldonitrile penta-acetate (ANPA) derivatisation method was compared with LC/IRMS without derivatisation. A large number of glucose standards and a variety of natural samples were analysed for five neutral carbohydrates at natural abundance as well as at (13)C-enriched levels. Gas chromatography/chemical ionisation mass spectrometry (GC/CIMS) was applied to check for incomplete derivatisation of the carbohydrate, which would impair the accuracy of the GC/IRMS method.The LC/IRMS technique provided excellent precision (±0.08‰ and ±3.1‰ at natural abundance and enrichment levels, respectively) for the glucose standards and this technique proved to be superior to GC/IRMS (±0.62‰ and ±19.8‰ at natural abundance and enrichment levels, respectively). For GC/IRMS measurements the derivatisation correction and the conversion of carbohydrates into CO2 had a considerable effect on the measured δ(13)C values. However, we did not find any significant differences in the accuracy of the two techniques over the full range of natural δ(13)C abundances and (13)C-labelled glucose. The difference in the performance of GC/IRMS and LC/IRMS diminished when the δ(13)C values were measured in natural samples, because the chromatographic performance and background correction became critical factors, particularly for LC/IRMS. The derivatisation of carbohydrates for the GC/IRMS method was complete.Although both LC/IRMS and GC/IRMS are reliable techniques for compound-specific stable carbon isotope analysis of carbohydrates (provided that derivatisation is complete and the calibration requirements are met), LC/IRMS is the technique of choice. The reasons for this are the improved precision, simpler sample preparation, and straightforward isotopic calibration.Copyright © 2015 John Wiley & Sons, Ltd.

相关化合物

结构式 名称/CAS号 全部文献
氢氧化钠 结构式 氢氧化钠
CAS:1310-73-2
过硫酸钠 结构式 过硫酸钠
CAS:7775-27-1
氢氧化钾 结构式 氢氧化钾
CAS:1310-58-3
乙酸酐 结构式 乙酸酐
CAS:108-24-7
3-乙基-2,4-戊烷二酮 结构式 3-乙基-2,4-戊烷二酮
CAS:1540-34-7
吡啶 结构式 吡啶
CAS:110-86-1
炭黑 结构式 炭黑
CAS:1333-86-4
氨 结构式
CAS:7664-41-7
甲烷 结构式 甲烷
CAS:74-82-8
AMMONIA (14N) 结构式 AMMONIA (14N)
CAS:1026405-88-8