Rapid Communications in Mass Spectrometry 2015-12-15

A membrane introduction mass spectrometer utilizing ion-molecule reactions for the on-line speciation and quantitation of volatile organic molecules.

Nicholas G Davey, Ryan J Bell, Erik T Krogh, Chris G Gill

文献索引:Rapid Commun. Mass Spectrom. 29 , 2187-94, (2015)

全文:HTML全文

摘要

The ability of membrane introduction mass spectrometry to quantitatively resolve low molecular weight volatile organic compounds (VOCs) such as benzene, toluene, ethylbenzene and xylene (BTEX) using electron ionization (EI) can be compromised by isobaric interferences. This work focuses on reducing isobaric interferences with ion-molecule reactions in a portable quadrupole ion trap mass spectrometer for the analysis of VOCs.EI was used to produce reagent ions from precursors (chloroform, methyl iodide, trichloroethylene or chlorobenzene) that were continually infused into the helium acceptor phase upstream of the membrane introduction mass spectrometry (MIMS) sampling interface. The reagent ions were selectively stored in the ion trap, and then allowed to react with target VOC analytes in air samples via ion-molecule reactions within the trap storage volume. A variety of reaction times were examined (50-5000 ms), and the resulting product ions were analyzed in positive ion mode.The detection limits achieved were comparable with those obtained using EI (low ppbv), and in some cases better than for EI coupled with tandem mass spectrometry (MS/MS). For the VOCs studied, isobaric interferences were greatly reduced or eliminated using chloroform as a reagent gas. The predominant ionization mechanism was via adduct formation, although charge transfer and hydride abstractions were also observed. An internal standard was shown to be effective at correcting for signal changes due to consumption of reagent ions when complex mixtures were sampled.Ion-molecule reactions were exploited to eliminate isobaric interferences that are often encountered in direct, real-time analysis strategies for atmospheric VOC mixtures. The use of a continuously infused internal standard will improve quantitative results in field applications where analyte concentration and sample complexity may be wide ranging.Copyright © 2015 John Wiley & Sons, Ltd.

相关化合物

结构式 名称/CAS号 全部文献
氯仿 结构式 氯仿
CAS:67-66-3
八甲基三硅氧烷 结构式 八甲基三硅氧烷
CAS:107-51-7
氘代氯仿-d 结构式 氘代氯仿-d
CAS:865-49-6
六甲基二硅氧烷 结构式 六甲基二硅氧烷
CAS:107-46-0
氯苯 结构式 氯苯
CAS:108-90-7
1,1-二氯乙烯 结构式 1,1-二氯乙烯
CAS:75-35-4
碘甲烷 结构式 碘甲烷
CAS:74-88-4
甲基碘-12C 结构式 甲基碘-12C
CAS:1173018-72-8