前往化源商城

Journal of Chromatographic Science 2013-01-01

HPLC-fluorescence method for measurement of the uremic toxin indoxyl sulfate in plasma.

Mohammed Al Za'abi, Badreldin Ali, Mohammed Al Toubi

文献索引:J. Chromatogr. Sci. 51(1) , 40-3, (2013)

全文:HTML全文

摘要

A sensitive and reproducible high-performance liquid chromatography-fluorescence method was developed and validated for quantitative determination of indoxyl sulfate in plasma using methyl paraben as an internal standard. The separation was carried out on an OSD-2 C18 Spherisorb column by isocratic elusion with sodium acetate buffer (pH 4.5) and acetonitrile (10:90, v/v) as the mobile phase. The method was validated and found to be linear in the range of 2.5 to 50 µM. The limit of quantification was 2.0 µM. The variations for intra-day and inter-day precision were less than 10.1%, and the accuracy values were between 93.4 and 102.5%. The extraction recoveries were more than 89%.

相关化合物

结构式 名称/CAS号 全部文献
乙酸钠 结构式 乙酸钠
CAS:127-09-3
乙酸钠,三水 结构式 乙酸钠,三水
CAS:6131-90-4
尼泊金甲酯 结构式 尼泊金甲酯
CAS:99-76-3