Analytical and Bioanalytical Chemistry 2004-03-01

Voltammetric determination of Ioxynil and 2-methyl-3-nitroaniline using C(18) modified carbon paste electrodes.

C Faller, A Meyer, G Henze

Index: Anal. Bioanal. Chem 356(3-4) , 279-83, (1996)

Full Text: HTML

Abstract

The stripping voltammetric behaviour of Ioxynil and 2-methyl-3-nitroaniline has been studied by means of a C(18) modified carbon paste electrode. The analytes are preconcentrated under open-circuit conditions (Ioxynil at pH 3.9; 2-methyl-3-nitroaniline at pH 10). For the determination of Ioxynil and 2-methyl-3-nitroaniline 0.01 mol/l HCl and 1 mol/l KOH, respectively, have been used as supporting electrolyte. Under optimized conditions detection limits up to 0.1 microg/ml Ioxynil and 0.3 microg/ml 2-methyl-3-nitroaniline have been obtained. The methods have been applied to the determination of Ioxynil and 2-methyl-3-nitroaniline in drinking water.


Related Compounds

Related Articles:

Microbial transformation of nitroaromatics in surface soils and aquifer materials.

1994-06-01

[Appl. Environ. Microbiol. 60(6) , 2170-5, (1994)]

[Different frequency of induction of liver tumors in reciprocal murine hybrids].

1996-05-01

[Dokl. Akad. Nauk. 348(1) , 129-31, (1996)]

Inhibition of the microsomal N-hydroxylation of 2-amino-6-nitrotoluene by a metabolite of methimazole.

1983-06-15

[Biochem. Biophys. Res. Commun. 113(2) , 433-8, (1983)]

More Articles...