Biomedical Chromatography 1999-10-01

Fluorimetric determination of D- and L-lactate derivatized with 4-(N, N-dimethylaminosulfonyl)-7-piperazino-2,1,3-benzoxadiazole (DBD-PZ) by high-performance liquid chromatography.

T Fukushima, S Adachi, H Ichihara, S Al-Kindy, K Imai

Index: Biomed. Chromatogr. 13(6) , 418-24, (1999)

Full Text: HTML

Abstract

A highly sensitive method, based on fluorescence derivatization with 4-N,N-dimethylaminosulfonyl-7-piperazino-2,1,3-benzoxadiazol e (DBD-PZ), was developed for the determination of D- and L-lactic acid. High-performance liquid chromatographic separation of the lactic acid derivative was achieved using an octadecylsilica column followed by enantiomeric separation on a phenylcarbamoylated beta-cyclodextrin chiral column. The separation factor for D, L-lactic acid derivatives was 1.30 using MeOH/H(2)O (80/20) as a mobile phase, and the detection limits were approximately 360 and 300 fmol on column for D- and L-lactic acid derivative, respectively. The proposed method was applied to determine D- and L-lactate in a wine and a lactic drink. Both D- and L-lactate could be determined simultaneously, with the precisions ranging from 3.50 to 5.78% for intra-day and 4.28-9.92% for inter-day determinations. The relative recovery was in the range of 91.6-100%.Copyright 1999 John Wiley & Sons, Ltd.


Related Compounds

Related Articles:

Sensitive fluorometric detection of prostaglandins by high performance liquid chromatography after precolumn labelling with 4-(N,N-dimethylaminosulphonyl)-7-(1-piperazinyl)-2,1,3-benzoxadiazole (DBD-PZ).

1992-01-01

[Biomed. Chromatogr. 6 , 143, (1992)]

Enantiomeric determination of D- and L-lactate in rat serum using high-performance liquid chromatography with a cellulose-type chiral stationary phase and fluorescence detection.

1999-05-01

[Anal. Biochem. 269(2) , 379-85, (1999)]

Development of an HPLC-fluorescence determination method for carboxylic acids related to the tricarboxylic acid cycle as a metabolome tool.

2005-12-01

[Biomed. Chromatogr. 19(10) , 788-95, (2005)]

A further study on the combined use of internal standard and isotope-labeled derivatization reagent for expansion of linear dynamic ranges in liquid chromatography-electrospray mass spectrometry.

2006-10-01

[Biomed. Chromatogr. 20(10) , 1049-55, (2006)]

Sensitive analytical method for the novel H1-receptor antagonist HSR-609 in human plasma and urine by high-performance liquid chromatography with pre-column fluorescent derivatization.

1996-12-13

[J. Chromatogr. B, Biomed. Appl. 687(2) , 419-25, (1996)]

More Articles...