Journal of chromatography. B, Biomedical sciences and applications 1997-06-20

Determination of simvastatin and its active metabolite in human plasma by column-switching high-performance liquid chromatography with fluorescence detection after derivatization with 1-bromoacetylpyrene.

H Ochiai, N Uchiyama, K Imagaki, S Hata, T Kamei

Index: J. Chromatogr. B. Biomed. Sci. Appl. 694(1) , 211-7, (1997)

Full Text: HTML

Abstract

By using a fluorescent derivatization and column-switching technique, a highly sensitive and selective high-performance liquid chromatographic (HPLC) method has been developed for the determination of simvastatin (I, beta-hydroxy-delta-lactone form) and its active hydrolyzed metabolite (II, beta,delta-dihydroxy acid form of I) in human plasma. A plasma sample spiked with internal standards was applied to a C8 solid-phase extraction column. Compounds I and II were separately extracted from plasma into two fractions. Compound I in one of the fractions was hydrolyzed to II. A fluorescent derivative was prepared by esterification of II with 1-bromoacetylpyrene in the presence of 18-crown-6 for both fractions. The pyrenacyl ester of II thus obtained was purified on a phenylboronic acid (PBA) solid-phase extraction column, and was measured by column-switching HPLC with fluorescence detection. The calibration curves for both I and II were linear in the concentration range of 0.1-10 ng/ml. The intra-day coefficients of variation were less than 11.0%, and the accuracies were between 91.7% and 117% within the concentration range for both analytes. The limits of quantification (LOQ) for both analytes were set to 0.1 ng/ml. This assay method has adequate sensitivity and selectivity to measure the concentrations of I and II in human plasma from clinical studies.


Related Compounds

Related Articles:

Li⁺ selective podand-type fluoroionophore based on a diphenyl sulfoxide derivative bearing two pyrene groups.

2011-01-01

[Molecules 16(8) , 6844-57, (2011)]

Probing solution behaviour of metallosupramolecular complexes using pyrene fluorescence.

2012-02-07

[Dalton Trans. 41(5) , 1568-73, (2012)]

In vitro bio-immunological and cytotoxicity studies of poly(2-oxazolines).

2011-07-01

[J. Mater. Sci. Mater. Med. 22(7) , 1725-34, (2011)]

Basis for a new procedure to eliminate diarrheic shellfish toxins from a contaminated matrix.

2002-01-16

[J. Agric. Food Chem. 50(2) , 400-5, (2002)]

Determination of dialkyl phosphates as breakdown products of organophosphorus insecticides in fruit juices by HPTLC with fluorescence detection.

2009-01-01

[J. AOAC Int. 92(3) , 691-8, (2009)]

More Articles...