Journal of Chromatography B 2007-09-15

Quantitative analysis of monofluoroacetate in biological samples by high-performance liquid chromatography using fluorescence labeling with 9-chloromethylanthracene.

Zhenming Xie, Wenbing Shi, Lan Liu, Qinying Deng

Index: J. Chromatogr. B. Analyt. Technol. Biomed. Life Sci. 857(1) , 53-8, (2007)

Full Text: HTML

Abstract

A rapid and sensitive RP-HPLC method with fluorescence detection has been developed for the quantitative analysis of trace amounts of monofluoroacetate (MFA) in biological samples as serum, food and meat. 9-Chloromethylanthracene (9-CMA) is used as the fluorescence labeling reagent. Samples were extracted and reacted with 9-chloromethylanthracene together with tetrabutylammonium bromide as catalyst at 80 degrees C for 50 min to give a new fluorescent derivative as 9-methyleneanthracene monofluoroacetate (MA-MFA). The resulting MA-MFA was characterized with IR, (1)H NMR, (13)C NMR and MS. Chromatography separation is performed on an Agilent Hypersil ODS column with a fluorescent detector employed with the excitation and emission wavelengths as 256 nm and 412 nm, respectively. Optimal conditions for derivatization, fluorescence detection and chromatographic separation have been established. The novel method yields a good linear relationship when the MFA concentration in serum within 1 and 250 ng/mL (r=0.9988). The detection limit (signal-to-noise ratio=3 with 2 microL injected) was 0.25 ng/mL. The practical applicability of this method was demonstrated by quantitative determination of MFA-Na in a blood sample from a person who had ingested the poison.


Related Compounds

Related Articles:

Efficient and rapid template-directed nucleic acid copying using 2'-amino-2',3'-dideoxyribonucleoside-5'-phosphorimidazolide monomers.

2009-10-14

[J. Am. Chem. Soc. 131(40) , 14560-70, (2009)]

Methotrexate-loaded biodegradable polymeric micelles: preparation, physicochemical properties and in vitro drug release.

2005-08-01

[Colloids Surf. B Biointerfaces 44(2-3) , 104-9, (2005)]

Liquid chromatographic determination of okadaic acid and dinophysistoxin-1 in shellfish after derivatization with 9-chloromethylanthracene.

1996-01-19

[J. Chromatogr. A. 721(2) , 359-64, (1996)]

Comparison of different fluorimetric HPLC methods for analysis of acidic polyether toxins in marine phytoplankton.

2003-12-01

[Anal. Bioanal. Chem 377(7-8) , 1202-6, (2003)]

Confirmation of okadaic acid, dinophysistoxin-1 and dinophysistoxin-2 in shellfish as their anthrylmethyl derivatives using UV radiation.

2005-07-08

[J. Chromatogr. A. 1080(2) , 148-56, (2005)]

More Articles...