Influence of a magnesium-fluoride coating of magnesium-based implants (MgCa0.8) on degradation in a rabbit model.
Martina Thomann, Christian Krause, Nina Angrisani, Dirk Bormann, Thomas Hassel, Henning Windhagen, Andrea Meyer-Lindenberg
Index: J. Biomed. Mater. Res. A 93(4) , 1609-19, (2010)
Full Text: HTML
Abstract
MgCa0.8 cylinders (2.5 x 25 mm(2)) were coated with a magnesium-fluoride layer and implanted in the marrow cavities of both tibiae of 10 New Zealand White rabbits. The implantation duration was 3 and 6 months. The implants were clinically well tolerated. Micro-computed tomography revealed a new bone formation at the edges of the implants as well as an endosteal and periosteal remodeling. Using EDX-analysis, a calcium and phosphorus rich degradation layer could be found on the implant surface. It was covered by an incomplete layer containing fluoride. The analysis by weight before implantation and after 3 and 6 months, respectively, showed a slight decrease in volume in comparison to uncoated implants. When compared with uncoated implants, the mechanical properties of the coated implants exhibited a reduction in strength after 3 months. After 6 months, the strength of the coated implants was higher than that of uncoated cylinders.(c) 2010 Wiley Periodicals, Inc.
Related Compounds
Related Articles:
2015-09-01
[Biol. Trace Elem. Res. 167 , 84-90, (2015)]
2015-08-28
[Nanoscale 7 , 13511-20, (2015)]
Machinable glass-ceramics forming as a restorative dental material.
2011-01-01
[Dent. Mater. J. 30(3) , 358-67, (2011)]
2012-12-03
[Angew. Chem. Int. Ed. Engl. 51(49) , 12242-5, (2012)]
2015-07-01
[J. Biomater. Appl. 30 , 104-18, (2015)]