Determination of the acaricide fenbutatin oxide in water samples by automated headspace-SPME-GC/MS.
Christophe Devos, Luc Moens, Pat Sandra
Index: J. Sep. Sci. 28 , 665, (2005)
Full Text: HTML
Abstract
The analysis of the acaricide fenbutatin oxide (FBTO) having a molecular weight of 1052.66 g mol(-1) in water samples by capillary GC/MS after in-situ derivatization with sodium tetraethylborate (NaBEt4) and headspace-SPME enrichment is described. Automated SPME is performed at 80 degrees C for 30 min. Detection is carried out in the ion monitoring mode with deuterated triphenyltin (TPhTd15) as internal standard. Good linearity (R2 = 0.9993) was obtained in the dynamic range 20 to 1000 ng L(-1) with a limit of detection of 16 ng L(1) (LOD at 3 S/N) and a limit of quantitation of 50 ng L(-1) (LOQ at 10 S/N). Intra-day RSD% for n=6 was 8.9 at the LOQ level.
Related Compounds
Related Articles:
2005-04-01
[Sci. Total Environ. 341(1-3) , 109-17, (2005)]
Reduction of spermatogenesis and steroidogenesis in mice after fentin and fenbutatin administration.
2006-09-30
[Toxicol. Lett. 166(1) , 53-9, (2006)]
2002-02-01
[Pest Manag. Sci. 58(2) , 123-30, (2002)]
2005-01-01
[Exp. Appl. Acarol. 36(1-2) , 61-70, (2005)]
1997-01-01
[Rapid Commun. Mass Spectrom. 11(2) , 159-64, (1997)]