Geophysical Research Letters 2000-07-15

Field intercomparison of a novel optical sensor for formaldehyde quantification.

S Friedfeld, M Fraser, D Lancaster, D Leleux, D Rehle, F Tittel

Index: Geophys. Res. Lett. 27(14) , 2093-6, (2000)

Full Text: HTML

Abstract

A one-week in situ intercomparison campaign was completed on the Rice University campus for measuring HCHO using three different techniques, including a novel optical sensor based on difference frequency generation (DFG) operating at room temperature. Two chemical derivatization methods, 2,4-dinitrophenylhydrazine (DNPH) and o-(2,3,4,5,6-pentafluorobenzyl) hydroxylamine (PFBHA), were deployed during the daylight hours for three- to four-hour time-integrated samples. A real-time optical sensor based on laser absorption spectroscopy was operated simultaneously, including nighttime hours. This tunable spectroscopic source based on difference frequency mixing of two fiber-amplified diode lasers in periodically poled LiNb03 (PPLN) was operated at 3.5315 micrometers (2831.64 cm 1) to access a strong HCHO ro-vibrational transition free of interferences from other species. The results showed a bias of -1.7 and -1.2 ppbv and a gross error of 2.6 and 1.5 ppbv for DNPH and PFBHA measurements, respectively, compared with DFG measurements. These results validate the DFG sensor for time-resolved measurements of HCHO in urban areas.


Related Compounds

Related Articles:

Identification of stable cytotoxic factors in the gas phase extract of cigarette smoke and pharmacological characterization of their cytotoxicity.

2013-12-06

[Toxicology 314(1) , 1-10, (2013)]

Characterisation and calibration of active sampling Solid Phase Microextraction applied to sensitive determination of gaseous carbonyls.

2012-01-15

[Talanta 88 , 252-8, (2012)]

Rapid determination of acetone in human blood by derivatization with pentafluorobenzyl hydroxylamine followed by headspace liquid-phase microextraction and gas chromatography/mass spectrometry.

2005-01-01

[Rapid Commun. Mass Spectrom. 19(5) , 647-53, (2005)]

Analysis of 3'-phosphoglycolaldehyde residues in oxidized DNA by gas chromatography/negative chemical ionization/mass spectrometry.

2003-12-01

[Chem. Res. Toxicol. 16(12) , 1560-6, (2003)]

Determination of carbonyl compounds in pool water with O-(2,3,4,5,6-pentafluorobenzyl)hydroxyamine hydrochloride and gas chromatographic-tandem mass spectrometric analysis.

2004-08-13

[J. Chromatogr. A. 1046(1-2) , 293-6, (2004)]

More Articles...