Talanta 2012-10-15

Analytical performance of a lab-made concomitant metal analyzer to generate volatile species of Ag, Au, Cd, Cu, Ni, Sn and Zn using 8-hydroxyquinoline as a reaction media.

Julia Villanueva-Alonso, Elena Peña-Vázquez, Pilar Bermejo-Barrera

Index: Talanta 100 , 45-50, (2012)

Full Text: HTML

Abstract

This study evaluated the main parameters affecting Ag, Au, Cd, Cu, Ni, Sn and Zn vapor generation using a lab-made concomitant metal analyzer (CMA) as a reaction chamber and gas-liquid separator. The modifier used in the reaction media was 8-hydroxyquinoline, and Inductively-Coupled Plasma Optical Emission Spectrometry was used as detection technique. The performance of the lab-made concomitant analyzer was compared with the performance of a continuous flow gas-liquid separator and of a cyclonic spray chamber. Standards were prepared in acid media and included 1 mg L(-1) of Co as a catalyzer. The optimum concentrations of the reagents in the standards were: 450 mg L(-1) of 8-hydroxyquinoline and 0.4 M nitric acid. The optimum concentration of sodium borohydride to generate the vapors was 2.25% (w/v) (prepared in 0.4% (w/v) NaOH). The volatile species were swept from the CMA to the torch by an argon flow of 0.6 mL min(-1). The use of the CMA led to an improvement of the detection limits for some elements compared to conventional nebulization: 1.1 μg L(-1) for Ag, 7.0 μg L(-1) for Au and 4.3 μg L(-1) for Sn. The limit of detection for Cu was 1.4 μg L(-1) and for Ni 22.5 μg L(-1). The direct mixing of the reagents on the spray chamber was not effective for Cd and Zn; a deviation of the linearity was observed for these elements.Copyright © 2012 Elsevier B.V. All rights reserved.


Related Compounds

Related Articles:

Selective growth-inhibitory effect of 8-hydroxyquinoline towards Clostridium difficile and Bifidobacterium longum subsp. longum in co-culture analysed by flow cytometry.

2014-12-01

[J. Med. Microbiol. 63(Pt 12) , 1663-9, (2014)]

Translating clinical findings into knowledge in drug safety evaluation--drug induced liver injury prediction system (DILIps).

2011-12-01

[J. Sci. Ind. Res. 65(10) , 808, (2006)]

Developing structure-activity relationships for the prediction of hepatotoxicity.

2010-07-19

[Chem. Res. Toxicol. 23 , 1215-22, (2010)]

A predictive ligand-based Bayesian model for human drug-induced liver injury.

2010-12-01

[Drug Metab. Dispos. 38 , 2302-8, (2010)]

New 2,3-diaminopropionic acid inhibitors of AGE and ALE formation.

2013-02-07

[Org. Biomol. Chem. 11(5) , 773-80, (2013)]

More Articles...