Journal of chromatography. A 2014-08-22

Sorptive extraction using polydimethylsiloxane/metal-organic framework coated stir bars coupled with high performance liquid chromatography-fluorescence detection for the determination of polycyclic aromatic hydrocarbons in environmental water samples.

Cong Hu, Man He, Beibei Chen, Cheng Zhong, Bin Hu

Index: J. Chromatogr. A. 1356 , 45-53, (2014)

Full Text: HTML

Abstract

In this work, metal-organic frameworks (MOFs, Al-MIL-53-NH₂) were synthesized via the hydrothermal method, and novel polydimethylsiloxane/metal-organic framework (PDMS/MOFs, PDMS/Al-MIL-53-NH₂)-coated stir bars were prepared by the sol-gel technique. The preparation reproducibility of the PDMS/MOFs-coated stir bar was good, with relative standard deviations (RSDs) ranging from 4.8% to 14.9% (n=7) within one batch and from 6.2% to 16.9% (n=6) among different batches. Based on this fact, a new method of PDMS/MOFs-coated stir bar sorptive extraction (SBSE) and ultrasonic-assisted liquid desorption (UALD) coupled with high performance liquid chromatography-fluorescence detection (HPLC-FLD) was developed for the determination of polycyclic aromatic hydrocarbons (PAHs) in environmental water samples. To obtain the best extraction performance for PAHs, several parameters affecting SBSE, such as extraction time, stirring rate, and extraction temperature, were investigated. Under optimal experimental conditions, wide linear ranges and good RSDs (n=7) were obtained. With enrichment factors (EFs) of 16.1- to 88.9-fold (theoretical EF, 142-fold), the limits of detection (LODs, S/N=3) of the developed method for the target PAHs were found to be in the range of 0.05-2.94 ng/L. The developed method was successfully applied to the analysis of PAHs in Yangtze River and East Lake water samples.Copyright © 2014 Elsevier B.V. All rights reserved.


Related Compounds

Related Articles:

Potentiometric determination of trace amounts of aluminium utilizing polyvinyl chloride membrane and coated platinum sensors based on E-N'-(2-hydroxy-3-methoxybenzylidene) benzohydrazide.

2013-01-01

[J. AOAC Int. 96(1) , 204-11, (2013)]

Using membrane transporters to improve crops for sustainable food production.

2013-05-02

[Nature 497(7447) , 60-6, (2013)]

Diagnostic use of cerebral and extracerebral oxysterols.

2004-02-01

[Clin. Chem. Lab Med. 42(2) , 186-91, (2004)]

Levels of 7-oxocholesterol in cerebrospinal fluid are more than one thousand times lower than reported in multiple sclerosis.

2005-02-01

[J. Lipid Res. 46(2) , 191-5, (2005)]

Disruption of thiol homeostasis and nitrosative stress in the cerebrospinal fluid of patients with active multiple sclerosis: evidence for a protective role of acetylcarnitine.

2003-09-01

[Neurochem. Res. 28(9) , 1321-8, (2003)]

More Articles...