Journal of the American Society for Mass Spectrometry 2007-01-01

Determination of synthetic ferric chelates used as fertilizers by liquid chromatography-electrospray/mass spectrometry in agricultural matrices.

Ana Alvarez-Fernández, Irene Orera, Javier Abadía, Anunciación Abadía

Index: J. Am. Soc. Mass Spectrom. 18(1) , 37-47, (2007)

Full Text: HTML

Abstract

A high-performance liquid chromatography-electrospray ionization/mass spectrometry (time of flight) method has been developed for the simultaneous determination of synthetic Fe(III)-chelates used as fertilizers. Analytes included the seven major Fe(III)-chelates used in agriculture, Fe(III)-EDTA, Fe(III)-DTPA, Fe(III)-HEDTA, Fe(III)-CDTA, Fe(III)-o,oEDDHA, Fe(III)-o,pEDDHA, and Fe(III)-EDDHMA, and the method was validated using isotope labeled (57)Fe(III)-chelates as internal standards. Calibration curves had R values in the range 0.9962-0.9997. Limits of detection and quantification were in the ranges 3-164 and 14-945 pmol, respectively. Analyte concentrations could be determined between the limits of quantification and 25 muM (racemic and meso Fe(III)-o,oEDDHA and Fe(III)-EDDHMA) or 50 muM (Fe(III)-EDTA, Fe(III)-HEDTA, Fe(III)-DTPA, Fe(III)-CDTA and Fe(III)-o,pEDDHA). The average intraday repeatability values were approximately 0.5 and 5% for retention time and peak area, respectively, whereas the interday repeatability values were approximately 0.7 and 8% for retention time and peak area, respectively. The method was validated using four different agricultural matrices, including nutrient solution, irrigation water, soil solution, and plant xylem exudates, spiked with Fe(III)-chelate standards and their stable isotope-labeled corresponding chelates. Analyte recoveries found were in the ranges 92-101% (nutrient solution), 89-102% (irrigation water), 82-100% (soil solution), and 70-111% (plant xylem exudates). Recoveries depended on the analyte, with Fe(III)-EDTA and Fe(III)-DTPA showing the lowest recoveries (average values of 87 and 88%, respectively, for all agricultural matrices used), whereas for other analytes recoveries were between 91 and 101%. The method was also used to determine the real concentrations of Fe(III)-chelates in commercial fertilizers. Furthermore, the method is also capable of resolving two more synthetic Fe(III)-chelates, Fe(III)-EDDHSA and Fe(III)-EDDCHA, whose exact quantification is not currently possible because of lack of commercial standards.


Related Compounds

Related Articles:

In vivo epithelial wound repair requires mobilization of endogenous intracellular and extracellular calcium.

2013-11-22

[J. Biol. Chem. 288(47) , 33585-97, (2013)]

Polyamine-polycarboxylate metal complexes with different biological effectiveness as nitric oxide scavengers. Clues for drug design.

2008-06-12

[J. Med. Chem. 51(11) , 3250-60, (2008)]

Influence of soil type on the mobility and bioavailability of chelated zinc.

2007-05-02

[J. Agric. Food Chem. 55(9) , 3568-76, (2007)]

Speciation of Zn-aminopolycarboxylic complexes by electrospray ionization mass spectrometry and ion chromatography with inductively coupled plasma mass spectrometry.

2009-02-01

[Rapid Commun. Mass Spectrom. 23(3) , 419-24, (2009)]

Equilibrium, kinetic and solvent effect studies on the reactions of [RuIII(Hedta)(H2O)] with thiols.

2005-12-21

[Dalton Trans. (24) , 3921-6, (2005)]

More Articles...