Clinica Chimica Acta 2015-03-10

Quantitative analytical method to evaluate the metabolism of vitamin D.

A Mena-Bravo, C Ferreiro-Vera, F Priego-Capote, M A Maestro, A Mouriño, J M Quesada-Gómez, M D Luque de Castro

Index: Clin. Chim. Acta 442 , 6-12, (2015)

Full Text: HTML

Abstract

A method for quantitative analysis of vitamin D (both D2 and D3) and its main metabolites - monohydroxylated vitamin D (25-hydroxyvitamin D2 and 25-hydroxyvitamin D3) and dihydroxylated metabolites (1,25-dihydroxyvitamin D2, 1,25-dihydroxyvitamin D3 and 24,25-dihydroxyvitamin D3) in human serum is here reported. The method is based on direct analysis of serum by an automated platform involving on-line coupling of a solid-phase extraction workstation to a liquid chromatograph-tandem mass spectrometer. Detection of the seven analytes was carried out by the selected reaction monitoring (SRM) mode, and quantitative analysis was supported on the use of stable isotopic labeled internal standards (SIL-ISs). The detection limits were between 0.3-75pg/mL for the target compounds, while precision (expressed as relative standard deviation) was below 13.0% for between-day variability. The method was externally validated according to the vitamin D External Quality Assurance Scheme (DEQAS) through the analysis of ten serum samples provided by this organism. The analytical features of the method support its applicability in nutritional and clinical studies targeted at elucidating the role of vitamin D metabolism. Copyright © 2015 Elsevier B.V. All rights reserved.


Related Compounds

Related Articles:

Diclofenac toxicity in human intestine ex vivo is not related to the formation of intestinal metabolites.

2015-01-01

[Arch. Toxicol. 89(1) , 107-19, (2015)]

Profiling of regioisomeric triacylglycerols in edible oils by supercritical fluid chromatography/tandem mass spectrometry.

2014-09-01

[J. Chromatogr. B. Analyt. Technol. Biomed. Life Sci. 966 , 193-9, (2014)]

Quantitative analysis of glycerol levels in human urine by liquid chromatography–tandem mass spectrometry

2014-04-15

[J. Chromatogr. B. Analyt. Technol. Biomed. Life Sci. 957 , 30-5, (2014)]

P7170, a novel inhibitor of mTORC1/mTORC2 and Activin receptor-like Kinase 1 (ALK1) inhibits the growth of non small cell lung cancer.

2014-01-01

[Mol. Cancer 13 , 259, (2014)]

Ultra-high-performance liquid chromatography electrospray ionization tandem mass spectrometry for accurate analysis of glycerophospholipids and sphingolipids in drug resistance tumor cells.

2015-02-13

[J. Chromatogr. A. 1381 , 140-8, (2015)]

More Articles...