Biomedical Chromatography 2011-10-01

A highly sensitive liquid chromatography tandem mass spectrometry method for simultaneous quantification of midazolam, 1'-hydroxymidazolam and 4-hydroxymidazolam in human plasma.

Henriette de Loor, Hylke de Jonge, Kristin Verbeke, Yves Vanrenterghem, Dirk R Kuypers

Index: Biomed. Chromatogr. 25(10) , 1091-8, (2011)

Full Text: HTML

Abstract

A highly sensitive liquid chromatography-tandem mass spectrometry method for the simultaneous quantification of midazolam and its major metabolites 1'-hydroxymidazolam and 4-hydroxymidazolam in human plasma was developed and validated. Stable isotope-labeled midazolam-D(4) and 1'-hydroxymidazolam-D(4) were used as internal standards. Compounds were extracted from 0.5 mL plasma by liquid-liquid extraction with ethyl acetate-heptane (1:4). Chromatography was achieved using a Sunfire C(18) column. The mobile phase was a gradient with 10 m m formic acid in Milli-Q water and methanol at a flow rate of 0.3 mL/min. Total run time was 10 min. Detection was performed using a tandem mass spectrometer with positive electrospray ionization. Calibration curves were linear over the range of 0.10-50.0 ng/mL for midazolam and 0.025-25.0 ng/mL for both metabolites. For all compounds the lower limit of quantification was 0.10 ng/mL. Imprecision was assessed according to the NCCLS EP5-T guideline and was below 10% for all compounds. Mean recoveries were between 94 and 109% for midazolam and its metabolites. The validated method was successfully applied in a pharmacokinetic study investigating in vivo CYP3A-activity in a large cohort of renal allograft recipients using sub-therapeutic doses of midazolam as a drug-probe.Copyright © 2010 John Wiley & Sons, Ltd.


Related Compounds

Related Articles:

A comparison of the metabolism of midazolam in C57BL/6J and hepatic reductase null (HRN) mice.

2014-12-15

[Biochem. Pharmacol. 92(4) , 701-11, (2014)]

Systematic evaluation of commercially available ultra-high performance liquid chromatography columns for drug metabolite profiling: optimization of chromatographic peak capacity.

2014-12-29

[J. Chromatogr. A. 1374 , 122-33, (2014)]

Species differences and substrate specificity of CYP3A heteroactivation by efavirenz.

2015-04-01

[Xenobiotica 45(4) , 345-52, (2015)]

Development of Murine Cyp3a Knockout Chimeric Mice with Humanized Liver.

2015-08-01

[Drug Metab. Dispos. 43 , 1208-17, (2015)]

Inhibition and kinetics of cytochrome P4503A activity in microsomes from rat, human, and cdna-expressed human cytochrome P450.

1996-09-01

[Drug Metab. Dispos. 24(9) , 940-7, (1996)]

More Articles...