Validation of a method for the simultaneous quantification of chloroquine, desethylchloroquine and primaquine in plasma by HPLC-DAD
Lina Zuluaga-Idárraga, Natalia Yepes-Jiménez, Carlos López-Córdoba, Silvia Blair-Trujillo
Index: J. Pharm. Biomed. Anal. 95 , 200-6, (2014)
Full Text: HTML
Abstract
• Chloroquine, desethyl chloroquine and primaquine level were quantified simultaneously by HPLC-DAD. • The method validation parameters were adequate according international standards. • Sample preparation procedure is easy and inexpensive. • The method was successfully applied to plasma patient samples. • The method is suitable to carry out therapeutic efficacy studies.