PLoS ONE 2015-01-01

Detection of clenbuterol hydrochloride residuals in pork liver using a customized surface plasmon resonance bioanalyzer.

Jiandong Hu, Ruipeng Chen, Shun Wang, Tingting Wang, Yuanyuan Zhao, Jianwei Li, Xinran Hu, Hao Liang, Juanhua Zhu, Xiaohui Sun, Liuzheng Ma, Min Jiang

Index: PLoS ONE 10(3) , e0122005, (2015)

Full Text: HTML

Abstract

A surface plasmon resonance (SPR) immunoassay with an immobilization of self-assembled molecular identification membrane for the detection of residual Clenbuterol Hydrochloride (CLB) in pork liver was systematically investigated and experimentally validated for its high performance. SPR immunoassay with a regular competitive inhibition assay cannot be directly verified to detect CLB residuals. In this study, the binding of Au film with mercaptopropionic acid was investigated using the known form of the strong S-Au covalent bonds formed by the chemical radical of the mercaptopropionic acid and the Au film. After that, the immunoglobulin IgG of swine (SwIgG-CLB) was bonded with the mercaptopropionic acid by covalent -CO-NH- amide bonding. The modified comprehensive analysis of how the membrane structure works was introduced together with the customized SPR bioanalyzer. In order to evaluate the performance of this biomembrane structure, the concentrations of CLB-contained solutions of 0 ng · mL(-1), 10 ng · mL(-1), 20 ng · mL(-1), 33.3 ng · mL(-1), and 40 ng · mL(-1) were prepared by adding CLB reagents into the solutions of CLB antibody (Clenbuterol Hydrochloride Antibody, CLB-Ab), successively and then the response unit (RU) was measured individually. Using the data collected from the linear CCD array, the fitting curve was established with the R-Square value of 0.9929. Correspondingly, the recovery rate ranged from 88.48% to 103.21% was experimented and the limit of detection of CLB in 1.26 ng · mL(-1) was obtained efficiently. It was concluded that the detection method associated with biomembrane properties is expected to contribute much to the determination of residual CLB in pork liver quantitatively by using the customized SPR bioanalyzer.


Related Compounds

Related Articles:

Acetonitrile adduct formation as a sensitive means for simple alcohol detection by LC-MS.

2014-11-01

[J. Am. Soc. Mass Spectrom. 25(11) , 1987-90, (2014)]

Silica-based nanofibers for electrospun ultra-thin layer chromatography.

2014-10-17

[J. Chromatogr. A. 1364 , 261-70, (2014)]

Acidogenic fermentation of Scenedesmus sp.-AMDD: Comparison of volatile fatty acids yields between mesophilic and thermophilic conditions.

2016-01-01

[Bioresour. Technol. 200 , 624-30, (2015)]

Characterization of the Intestinal Lactobacilli Community following Galactooligosaccharides and Polydextrose Supplementation in the Neonatal Piglet.

2015-01-01

[PLoS ONE 10 , e0135494, (2015)]

Organic monolith frits encased in polyether ether ketone tubing with improved durability for liquid chromatography.

2015-09-01

[J. Sep. Sci. 38 , 2938-44, (2015)]

More Articles...